Datasheet

Series AMEC15-MAZ
15 Watt | AC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 052e R8.N 1 of 5 North America only
FEATURES:
Connector on Input & Output RoHS compliant
Operating temperature: -40 to +80°C Soft start
Over load, Over Voltage, Short Circuit Protection Energy Star compliant
Optional DIN Rail mounting bracket CE, cULus, CB approvals
Universal input:
90-264VAC, 47-440Hz 4000VAC I/O Isolation
Models
Single output
Model
Input Voltage
(VAC/Hz)
Input voltage
(VDC)
Output
Voltage
(V)
Output
Current
max (A)
Maximum
Capacitive Load
(µF)
Efficiency
(%)
AMEC15-3.3SMAZ 90-264/47-440 120-370 3.3 3 4700 74
AMEC15-5SMAZ 90-264/47-440 120-370 5 3 2200 78
AMEC15-12SMAZ 90-264/47-440 120-370 12 1.25 1000 81
AMEC15-15SMAZ 90-264/47-440 120-370 15 1 680 81
AMEC15-24SMAZ 90-264/47-440 120-370 24 0.63 470 83
Models
Dual output
Model
Input Voltage
(VAC/Hz)
Input voltage
(VDC)
Output
Voltage
(V)
Output
Current
max (A)
Maximum
Capacitive Load
(µF)
Efficiency
(%)
AMEC15-5DMAZ 90-264/47-440 120-370 ±5 ±1.5 ±1000* 78
AMEC15-12DMAZ 90-264/47-440 120-370 ±12 ±0.63 ±470* 80
AMEC15-15DMAZ 90-264/47-440 120-370 ±15 ±0.5 ±330* 81
Input Specifications
Parameters Conditions Typical Maximum Units
Current
115VAC 350 mA
230VAC 180 mA
Inrush current <2ms
115 VAC 10 A
230 VAC 20 A
Leakage current
115 VAC 0.1 mA
264 VAC 0.2 mA
External Fuse (recommend) slow blow type 2 A
Input Dissipation No load <0.5 W
Under Voltage Protection 88 VAC
Output Specifications
Parameters Conditions Typical Maximum Units
Voltage accuracy ±2 %
Line regulation LL-HL ±0.5 %
Load regulation (single output) 0-100% ±0.5 %
Cross regulation (dual output) 25% load - 1
s
t
out, 100% load – 2
n
d
out ±5 %
Transient Recovery Time 200 µs
Transient Recovery Deviation 25% load step ±2 % of Vout
Ripple & Noise* 20MHz bandwidth 100 mVp-p
Hold-up time min 20 ms
*Ripple & Noise measured with 1μF M/C and 47μF E/C
CB