Datasheet
Series AMEC15-MAZ
15 Watt | AC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 052e R8.N 2 of 5 North America only
Isolation Specifications
Parameters Conditions Typical Rated Units
Tested I/O voltage 3sec 4000 VAC
Isolation resistance >1000 MΩ
General Specifications
Parameters Conditions Typical Maximum Units
Switching frequency 132 KHz
Start up time 900 mS
Over load protection Auto recovery, hiccup mode >131 %
Over voltage protection Zener diode clamp
Short Circuit protection Continuous
Short Circuit restart Auto recovery
Operating temperature With derating over 55
o
C (10CFM) -40 to +80
o
C
Storage temperature -50 to +100
o
C
Max Case temperature 100
o
C
Temperature coefficient ±0.02 % /
o
C
Cooling Free air convection
Humidity 95 % RH
Weight 100 g
Dimensions (L x W x H) 3.62 x 2.56 x 0.94 inches 92.0 x 65.0 x 24.0 mm
MTBF > 400 000hrs (MIL-HDBK -217F, t=+25
o
C)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Parameters Conditions
Shock
Wave form: Half sine wave
Acceleration amplitude: 5gn
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Vibrations
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety & EMC Specifications
Parameters
Agency approvals cULus, CE, CB
Standards
Medical Electrical Equipment
IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90
Information technology Equipment EN 60950-1:2006+A11:2009
Harmonic Current Emissions IEC/EN 61000-3-2, (EN60555-2)
EMI - Conducted and radiated emission EN55011, class B
Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity IEC 61000-4-2
RF, Electromagnetic Field Immunity IEC 61000-4-3
Electrical Fast Transient/Burst Immunity IEC 61000-4-4
Surge Immunity IEC 61000-4-5
RF, Conducted Disturbance Immunity IEC 61000-4-6
Power frequency Magnetic Field Immunity IEC 61000-4-8
Voltage dips, Short Interruptions Immunity IEC 61000-4-11