CHAPTER 5. PC-CONTROLLED FUNCTIONS
2.3. Function Setting
(1) Group call setting
Registers the following contents designating the representative master station/telephone.
Contents
Setting Item
Member Station Exchange Number
Member Station line Number
Sets the exchange number (1 16) of the master station or telephone.
Sets the Line number (1 4) of the master station (telephone).
(2) Call forwarding & time-out settings
Registers the following contents designating the exchange number (1 16).
Contents
Setting Item
Call Forwarding
Enable/Disables the Call Forwarding function.
Time-Based Call Forwarding
Enables/Disables the Time-Based Call Forwarding function by its start
and end times.
Time-Based Call Forwarding Start
Time
Sets the hour and minute the call forwarding interval will begin. (00:00
23:59)
Time-Based Call Forwarding End
Time
Sets the hour and minute the call forwarding interval will end. (00:00
23:59)
Busy Call Forwarding
Enables/Disables the Busy Call Forwarding function.
No-Answer Call forwarding
Enables/Disables the No-Answer Call forwarding function. If enabled,
calls are transferred when no response is detected within the preset
interval.
Sets the station calling interval (1 99 seconds).
Call Time-Out
Enables/Disables the call time-out function. If enabled, calls are
terminated when no response is made within the preset interval.
Sets the station calling interval (1 99 minutes).
Conversation Time-Out
Enables/Disables the Conversation Time-Out function. If enabled,
conversations are automatically terminated when the time limit is
reached.
Sets the conversation time limit (10 990 seconds).
(3) Scan monitor setting
Registers the following contents designating the master station.
Contents
Setting Item
Monitoring Time
Sets the scan-monitor time interval (1 99 seconds).
Monitoring Substation Exchange
Number
Sets the number of the exchange to which the substation is connected
(1 16).
Monitoring Substation Line Number
Sets the substation equipment number (1 64).
Monitoring Substation Number
Sets the substation number.
Monitoring Substation Name
Sets the substation name.
(4) Paging setting
Registers the substations assigned to the zone designating the exchange number (1 16).
Contents
Setting Item
Zone Number Digit
Selects the length of the digit to be used to label the paging zone
numbers (1 2).
Paging Time-Out
Enables/Disables the Paging Time-Out function.
Zone
Resisters substation numbers (1 1024) for each zone.
Sets a Paging time limit (10 990 seconds).