205 A AX SERIES Integrated Security &Communication System AX-248C -1- INSTALLATION &OPERATION MANUAL
PRECAUTIONS General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water General Precautions WARNING (Negligence could result in death or serious injury to people) 1. High voltage is present internally. Do not open the case. Electric shock could result. 2. Do not dismantle or alter the unit. Fire or electric shock could result. 3. Do not connect any non-specified power source to the +, - terminals, and do not install two power supplies in parallel to a single input.
1 SYSTEM CONFIGURATIONS System Configurations Capacity External integration example, Door station Master station, Central exchange unit 2 PACKAGE CONTENTS Package contents (Mullion door station), (Vandal-resistant door station) Package contents (Master station), (16 call add-on selector), (Central exchange unit) 3 INSTALLATION Installation location (Master station), (Door station), Visible range Cable, Wiring distance 4 MOUNTING Mounting (Mullion door station) Mounting (Vandal-resistant door station) Door
RS-232C Max. 15 m CAT5e Max. 300 m CAT5e Max. 300 m Max. 32 CAT5e Max. 300 m CAT5e Max. 300 m CAT5e Max. 300 m Max. 24 CAT5e Max. 300 m [1] CAT5e Max. 300 m CAT5e Max. 300 m CAT5e Max. 300 m CAT5e Max. 300 m RS-232C Max. 15 m [1] CAT5e Max. 300 m CAT5e Max. 300 m CAT5e Max. 300 m CAT5e Max. 300 m 1 1-1 SYSTEM CONFIGURATIONS [2] Max. 32 -4- Max. 4 [4] Max. 8 AX-320C [5] [3] [6] AX-084C [3] AX-248C CAT5e AX-320C CAT5e AX-320C CAT5e PS DC 24 V 2A PS DC 24 V 2A Max.
1-1 1-2 System Configurations [1] Door station [2] Master station • A maximum of seven 16-call add-on selectors (AX-16SW) can be connected. [3] Central Exchange Unit • A maximum of three Add-on exchange units (AX-320C) can be connected.
1-3 1-4 c a PC AX-084C AX-248C a b d c c [1] IF-DA AX-DM b d c d AX-DV AX-DVF AX-DV-P AX-DVF-P IE-JA g e f d [3] e [4] g IE-SS(SOP) [2] h e External integration example [1] CCTV system [2] Access control system [3] AC transformer PT1210N (AC 12V, 10VA, for North America only) [4] Electric door strike EL-9S a. System log (RS-232C) b. Camera switching c Video signal d. Remote door release signal (RS-232C) e. Door release dry contact (N/O or N/C programmable) f.
1-5 [1] 1-6 [2] [1] [2] [3] [3] Central exchange unit [1] AX-084C Standard central exchange unit • A maximum of 4 master stations and 8 door stations can be connected. [2] AX-248C Expanded central exchange unit • A maximum of 8 master stations and 24 door stations can be connected. [3] AX-320C Add-on exchange unit • A maximum of 32 door stations can be connected. • A maximum of 3 add-on exchange units can be connected in a system.
2 2-1 [1] 2-2 PACKAGE CONTENTS [1] [2] [2] [3] [4] [5] [3] Package contents (Mullion door station) [1] AX-DM mullion audio door station [2] Mounting screws [3] Operation manual [6] Package contents (Vandal-resistant door station) [1] Vandal-resistant door station AX-DV, AX-DVF, AX-DV-P, AXDVF-P [2] Special screwdriver [3] Directory card [4] Mounting screws and Anchor bolts (AX-DV, AX-DV-P) [5] Mounting screws (AX-DVF, AX-DVF-P) [6] Back box (AX-DVF,AX-DVF-P) ∗ [5] and [6] are packed assembled wit
2-3 2-5 [1] [3] [2] [4] [1] [5] Package contents (Central exchange unit) [1] AX-084C, AX-248C, or AX-320C exchange unit [2] Mounting screws [3] Rack and wall mounting brackets x2 [4] Installation CD (AX-084C, AX-248C), including set-up software program and instruction manual.
3 3-1 3-3 INSTALLATION 185 cm 6'1" AX-DV AX-DVF AX-DV-P AX-DVF-P AX-DV AX-DVF AX-DV-P AX-DVF-P 65 cm 2'1" 120 cm 3'11" 150 cm 5' 50 cm 20" 50 cm / 20" 95 cm / 3'1" Visible range This is the range visible from the camera position. Installation location (Master station) Install the video master station in a place where the screen is not exposed to direct sunlight.
3-5 3-4 1 AX-DV AX-DV-P AX-DVF AX-DVF-P AX-8M AX-8MV D AX-DV AX-DM AX-DVF IF-DA AX-DV-P IE-JA AX-DVF-P IE-SS AX-8M + AX-16SW AX-8MV A AX-DM IF-DA IE-JA M B IE-SS CAT5e PS-2420UL PS-2420S PS-2420DIN CAT5e PS AX-084C AX-248C E1 C AX-248C AX-084C AX-248C E2 AX-248C AX-320C CAT5e AX-320C AX-320C AX-320C 12345678 D E3 12345678 AX-320C Pin 1 RJ-45 Plug AX-320C E4 AX-320C AX-320C 2 PS-2420UL PS-2420S PS-2420DIN PS Wiring distance CAT5e (24AWG) A 300 m (980') B 300 m (980') C D 5
4 4-1 MOUNTING 1 [1] 2 3 AX-DM 6 7 8 1 2 4 5 CAT5e 3 4 [3] [2] Ø16 mm 5/8" 142 mm 5-9/16" [3] 71 mm 2-13/16" Mounting (Mullion door station) 1. Connect the CAT5e cable to the rear of the AX-DM. Use wires #3 (white-green) and #6 (green) as one conductor, and #7 (white-brown) and #8 (brown) as the other conductor (RJ-45 jack not used at Mullion door station). The other pairs are not used. 2.
4-2 1 Mounting (Vandal-resistant door station) 1. Open the rear cover of the surface mount door station and insert the CAT5e cable (RJ45 plug). For the AX-DV-P, pass it through either the top or bottom cable inlet hole. For the AX-DV, pass it through the top cable inlet hole. 2. Mount as shown in figure 2. 3. Open the rear cover of the flush mount door station and insert the CAT5e cable. Pass cable through either the top or bottom cable inlet hole. 4. Mount as shown in figure 4. 5.
- 14 10 mm 3/8" 16 mm 5/8" 77 mm 3" 263 mm 10-3/8" (BOX) 16 mm 5/8" 26 mm 1" 10 mm 3/8" 60.5 mm 2-3/8" 82.5 mm 3-1/4" 167 mm 6-9/16" 214 mm 8-7/16" (BOX) 194 mm 7-5/8" 246 mm 9-11/16" 195 mm 7-11/16" 106.5 mm 4-3/16" 10 mm 3/8" 47.5 mm 1-7/8" 14 mm 9/16" 16 mm 5/8" 26 mm 1" 24 mm 15/16" [1] 16 mm 5/8" [2] Ø16 mm 5/8" 10 mm 3/8" [1] 47.5 mm 1-7/8" 26 mm 1" AX-DV-P 243 mm 9-9/16" 1.3 mm 8.5 mm 1/16" 5/16" 106.
4-3 Door station installation dimensions [1] Center position of camera [2] Wiring holes Ø 16 mm 5/8" - 15 -
4-4 [5] 1 AX-8M AX-8MV [2] [2] AX-16SW [3] [3] [6] 2 [1] AX-8M AX-8MV 3 149 mm 5-7/8" [7] a b 65 mm 2-9/16" 46 mm 1-13/16" [4] [4] - 16 - 83.
4-5 4-4 Mounting (Master station) 1. When using AX-16SW, connect the units with the supplied cable and secure with the joint bracket. Cut the joint bracket on the bottom right side of the AX-8M / AX-8MV. When utilizing more than one AX-16SW, it is necessary to cut the joint bracket installation section on all but the last module. 2. Remove the mounting bracket and insert the CAT5e cable (RJ45 plug). 3. The master station can either be wall or desk mounted. a.
5 5-1 WIRING [8] OP [7] AX-DV AX-DV-P AX-DVF AX-DVF-P IER-2 2 NP [9] AX-DM 1 E [3] [2] [14] M AX-8MV AX-8M Max. 7 AX-16SW RJ45 CAT5e D RJ45 IF-DA IE-JA [10] OP 1 2 CAT5e [13] [6] EL-9S 12345678 CAT5e AX-084C AX-248C [11] PC DC 24 V, 30 mA max.
5-1 Wiring Securely insert wires into each terminal as shown. [1] AX-248C or AX-084C central exchange unit [2] AX-8MV video master station or AX-8M master station AX-16SW 16 call add-on selector [3] Video or audio-only door station [4] AX-320C add-on exchange unit ID setting switch 1st unit: 2 2nd unit: 3 3rd unit: 4 [5] Power supply (DC 24 V,2 A) • Video system: 2 pcs 1. Connect 2 pcs of power supply separately for video and audio. • Audio system: 1 pce 2. Connect power supply as in the figure.
6 6-1 Names (Door station) [1] CALL button [2] Speaker [3] Microphone [4] Camera [5] Directory card [6] Proximity card reader [7] White LED NAMES AX-DV AX-DVF [4] [4] [7] [7] [3] [3] [5] [5] [2] [2] [1] [1] AX-DV-P AX-DVF-P [4] [4] [7] [7] [3] [3] [5] [5] [2] [2] [1] [1] [6] [6] AX-DM [2] [1] [3] - 20 -
6-2 Names (Master station) [1] Individual door station selector button (w/LED) [2] Individual master station selector button (w/LED) [3] Door release button (w/LED) [4] Scan monitor button (w/LED) [5] CO transfer button (w/LED) [6] Privacy button (w/LED) [7] TALK button (w/LED) [8] ALL CALL button [9] OFF button [10] Occupied LED [11] Speaker [12] Microphone [13] 3.
6-3 AX-084C [9] [3] [7] [8] [6] [1] [12] [2] [4] [5] [10] AX-248C [9] [8] [7] [6] [1] [12] [2] [4] [3] [5] [10] AX-320C [9] [1] [12] [4] [2] - 22 - [11] [10]
6-3 Names (Central exchange unit) [1] POWER switch [2] Door station port [3] Master station port [4] Add-on exchange unit port [5] CO line port [6] Setting/log port [7] Video output port [8] Video output trigger port [9] Door release relay port (L1 corresponds to door station D1, L2 to door station D2, etc.
7 7-1 SETTING UP 1 3 RS-232C AX-248C 2 [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] 3 - 24 - [11]
7-1 Setup tool ∗ Install the setup tool program on your PC (Windows ®) beforehand. • The setup software is on the CD that comes with the central exchange unit. • For installation (auto open), see startup.html. • A folder containing the setup tool is created on the desktop. 1. Connect the central exchange unit setting/log port and the PC with an RS-232C straight-thru cable (off-the-shelf). 2. Start the setup tool. (Double-click AxSetupEN.exe.) 3. The setup edit screen opens.
7-2 Starting the setup 1. Setup file and file operation • When the setup tool is started, the default data is read in and displayed. • To use a setup file other than the default: From the file menu, select "Open (O)", then select the appropriate setup file. The only permitted extension for setup files is "cfg". Relating this extension to the AX setup tool application is not supported. 2. New When you select "New (N)" from "File (F)", the setup data is created.
7-3 7-4 1 2 Master station setup input 1. Check the master units to be connected from among "No. 1" through "No. 8". 2. When you select each master station to be included, the selection of "w/LCD Monitor" or "w/o LCD Monitor" is required. Select setting based on which style of master station (AX-8MV or AX-8M) is connected to each input. 3 Central exchange unit setting 1. For the device used as "No.1", select "AX-084C" or "AX248C". 2.
7-5 1 [9] [1] [2] [3] [3] [4] [5] [6] [7] [8] [4] 2 3 - 28 -
7-5 Door station setting ∗ There are three methods for setting door stations: individual input, line copy-and-paste input, and column batch input. 1. Individual input [1] Central exchange unit number (cannot be input) • Displays the number of the central exchange unit to which the corresponding door station is connected. This cell cannot be input. [2] Number (cannot be input) • Displays the door station number displayed on the master station's LED display. This cell cannot be input.
7-6 Time out setting 1. "Call from Door St. (Normal)" time setting [1] The time setting is "10-600 Seconds" or "Infinite". To change the calling time, click "(10-600 Seconds)". [2] If you click the box displaying the number of seconds for calls, you can edit it and the spin button is displayed. [3] Pressing the top spin button increases the setting time, and pressing the bottom spin button decreases the setting time. It is not possible to change to a number that exceeds the upper or lower time limit.
7-7 7-8 1 Communication Method • "VOX or Press to Talk": Hands-free and press-to-talk communications are available. • "Press to Talk": Only press-to-talk communication is available. 2 CO Transfer 1. To allow transfer of a door station call to a CO line, click "Enable". Do disallow, click "Disable". 2. If CO Transfer is activated, select the CO line detection method. To detect the CO line through reverse polarity, select "Detect". If not, select "Do Not Detect".
7-10 New setting file 1 5 New Setup upload Normal start-up Default setting file (default.cfg) AX setup tool Save Save as default Any setup file (xxxxxx.
7-10 7-11 Uploading settings and save 1. Setup data flow 2. Setup download menu When you select "CEU (C)" from "Tool (T)" menu and select "Download (D)", the setup data stored in the CEU is downloaded to the PC. Before starts downloading, password input is required. At this time, all the setup data being edited with the PC is overwritten with the data downloaded from the central exchange unit. 3.
7-12 [6] [1] 1 [4] [5] 2 a d b c 3 - 34 - [2] [3]
7-12 7-13 System monitor 1. System monitor start • When you select "Start System Monitoring (M)" from "Tool (T)", the system monitor is started. The display switches from the setup edit screen to the system monitor screen. 2. System monitor screen operation On the system monitor screen, "Scan Monitor", "Door Station button", "Off", and "Door Release" command buttons can be clicked with the mouse.
7-14 7-15 Exiting the setup tool When you select "Exit (X)" from "File (F)", the setup tool closes. Help The version information dialog is displayed.
8 8-1 1 3 4 OPERATIONS 2 Calling a master station from door station and communicating There are two priority levels for calls from door stations, "Normal"and "Priority". 1. Press the door station CALL button. 2. The calling tone rings on the master station (for a normal call, an intermittent tremolo sound; for a priority call, a rapid intermittent tremolo sound) and the selector button LED for the individual door station flashes (two flashes in a row for a priority call).
8-3 8-2 Privacy (PRIV)function 1. To make the master into privacy mode (prevent monitoring from other stations), press the privacy button (LED lights up). 2. To cancel privacy mode, press the privacy button again (LED goes out). ∗ The privacy setting cannot be changed while in communication. 1 Privacy setting PRIV LED 2 3 Calling a master station from a master station and communicating 1. Press individual selector button of master station. 2.
8-4 8-5 1 1 2 2 3 3 CO line call from door station and communicating 1. If the CALL button is pressed at a door station while CO Transfer feature is set (with CO Transfer button lit), the call tone rings on the master station (for a normal call, an intermittent tremolo sound; for a priority call, a rapid intermittent tremolo sound) and the selector button LED for the individual door station flashes (two flashes in a row for a priority call).
8-6 2. During an All Call, if you press the individual master station selector button on the calling master station or press the individual master station selector button or TALK button on one of the other master stations, communications switch to hands-free between master stations. 3. There is no function for talk back from a called master station. 4. If you press down the ALL CALL button but do not start talking within 30 seconds, the system goes back to standby.
8-8 Door station status Standby Communicting with telephone Scan monitor Available Available: The communication continues as is and audio monitoring is not available. Communicting with master station Available: The communication continues as is and audio monitoring is not available. Monitoring Available: The communication continues as is and audio monitoring is not available. Calling Not available: The door station is skipped and the next door station is scanned. 1 2 Scan monitor 1.
8-11 List of function button operations for each own master station mode • Each operation is carried out when the audio channel is empty. • Even when a sub-station call only uses the video channel, the audio channel is also treated as filled. (The audio and video channels form a pair.
9 10 TECHNICAL PRECAUTIONS Technical precautions • Operating temperature: Door station: -10 ~ 60 °C (14 ~ 140 °F) Master station: 0 ~ 40 °C (32 ~ 104 °F) Central exchange unit: 0 ~ 40 °C (32 ~ 104 °F) • Cleaning: Clean the units with a soft cloth dampened with a neutral household cleanser. Do not use an abrasive cleaner or cloth. • Camera switching: Since the individual camera sync signal is a nonsynchronized signal, the image synchronization may be disrupted.
WARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of two years after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination shall disclose to be defective and under warranty.