Stereo System User Manual

- 3 -
English Français Español Nederlands Italiano
2-2 Wiring method, wiring distance
Wire the inside units from station-to-station (daisy-chained).
JK-1SD
JK-1MED/1MD
JK-DA
JK-DV
JK-DVF
2 4
PS18
PS-1820
PS-1810DIN
PS-1820DIN
A
B C
IER-2
2-3 Cable
1
Use PVC-coated cable with PE (polyethylene) insulation.
(x2)
2
Never use individual conductors, twisted pair cable or coaxial cable.
3
When using a cable with unused conductors, terminate both ends of
the unused pair(s) with a 120 resistor.
JK-1MED/1MD JK-1SD
120 120
+
-
A1
A2
B1
B2
L
L
S
S
+
-
SW
SW
B1
B2
Ø
0.65 mm 22 AWG
Ø
1.0 mm 18 AWG
A 50 m 165' 100 m 330'
B 5 m 16' 10 m 33'
C 75 m 245' 150 m 490'
3
MOUNTING
Mounting on a gang box
1
2
Mounting
screws x 2
1-gang box
UP
Wall mounting bracket
83.5 mm
(3-5/16")
8 mm
3/8"
1. Press RELEASE button. (This is performed to
release the lock or to securely insert wiring.)
2. Insert the cable into the terminal.
Surface wiring
JK-1SD_multi.indb 3 2008/12/12 0:09:21