CABLE
1
Use PVC jacket with PE
(polyethylene) insulated cable.
(×2)
3
When using a cable with unused
conductors, terminate both ends
of the unused pair(s) with a 120 Ω
resistor.
120Ω120Ω
B1
B2
B1
B2
Master
station
IP video intercom
adaptor
(Excess wires)
2
Never use individual conductors,
twisted pair cable or coaxial
cable.
4
Odd number cables, such as
three conductor wire, cannot be
used.
●
About LAN cables
● When installing LAN cables, do not bend them to an extent where the radius is 30 mm (1-3/16”) or less.
Communication failure could result.
Radius
≧
30 mm (1-3/16”)
LAN cable
Radius
<
30 mm (1-3/16”)
LAN cable
● Do not remove more of the LAN cable jacket than necessary.
Pair4
Pair3
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Pair2
Pair1
T568A
Pair4
Pair2
Pair3
Pair1
T568B
● Arrange the color code of the RJ45 connections in accordance with EIA/TIA-
568A and 568B.
MOUNTING
Install the unit on a shelf or wall in an area that will be accessible for future inspections, repairs, and
maintenance.
Be sure to install the unit so that each indicator can be checked.
●
When installing the unit on the wall
Unit
MADE IN JAPAN
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
・
2
1
Attach spacers to the wood mounting
screws, and then attach them to the
wall.
Attach the unit.
90 mm (3-17/32”)
Spacers
× 2
Wood mounting
screws × 2
AIPHONE JKW-IP
POWER
STATUS
LAN ACT
Object
30 mm (1-3/16”)
or more
When installing the unit on
the wall, allow at least 30 mm
(1/3/16
”
) of open space between
the unit and any objects in the
vicinity.
90 mm (3-17/32”)
Size of the gap between the screws
for installing the unit on the wall