Indoor Furnishings User Manual

CAUTION
* Do not connect any AC wires to any terminal on any unit, as damage may occur. Connect only specified power source to + and - terminals.
* Do not install more or different power sources than specified for the system.
* Do not attempt to install or connect wires on the NEM system while the system's power supply is plugged in.
* NEM masters and related equipment, unless specified as "weather resistant", are designed for indoor use only. Door stations (NE-DA, NE-JA,
NE-SS, NE-SSR and NE-NVP) may be installed outdoors in a protected area. Do not expose any equipment directly to rain or extreme weather
conditions.
IMPORTANT
* Any other manufacturer's products installed with the system (power supply, external device, etc.) are not covered under Aiphone's warranty.
* Do not mount NEM equipment in the following places, as it may cause the system to malfunction:
- High or extreme cold temperature areas: under direct sunlight, near equipment that varies in temperature, in front of air conditioner,
inside a refrigerated area, etc.
- Places subject to moisture or humidity extremes.
- Places subject to environmental conditions, such as dust, oil, chemicals, salt, etc.
* NEM units are electronic devices, which must not be subjected to water or any other liquid.
* Severe weather conditions, such as lightning storms, may cause damage to NEM equipment. We recommend that power surge protection be
installed to minimize potential component level damage.
- Install the SA-1 surge arrestor to protect the power supply from a surge.
- Additional SA-1 surge arrestors should be installed on all communication lines (one SA-1 for every two connected to master.).
For additional information about this system,
please refer to the standard NEM instructions.
OPERATION:
* POWER SWITCH ON MASTER MUST BE ON FOR SYSTEM TO BE OPERABLE.
1. When a station calls in, press the selector button corresponding to the lit LED. Station will continue to ring and
station LED will remain illuminated until the call is answered at the master or reset at the sub.
2. To speak to the person at the remote station, press the TALK button on the master, and release TALK button
to hear reply. If the master is equipped with a handset, communication can be with the handset or push-to-
talk. Communication via the handset is VOX (voice actuated).
3. When the conversation is completed, press the OFF button to the left of the station button that is selected.
Hang up handset.
Pg. 3
N-20,40AS Instr.
0108JD
Toll Free Technical Support:
1-800-692-0200
E-mail tech-serv@aiphone.com
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
TERMINAL LAYOUT:
+-
V1 A1 V2 A2
EEEEEEEEEE
+
+
Brass Jumper Brass Jumper
10 9 8 7 6 5
20 19 18 17 16 15 14 13 12 11
+
+
4321
10 9 8 7 6 5
20 19 18 17 16 15 14 13 12 11
+
+
4321
30 29 28 27 26 25
40 39 38 37 36 35 34 33 32 31
+
+
24 23 22 21 + - V1 A1 V2 A2
EEEEEEEEEE
+
+
Brass Jumper Brass Jumper
V3 A3 V4 A4
Brass JumperBrass Jumper
N-nAS TERMINAL DEFINITIONS:
+ Positive 24V DC
- Negative
1~40 Station number
E Common communication
V1-V4 Connects to NB-U for
A1-A4 Background Music
N-20AS
N-40AS