Instruction Manual

O AIPHONE
832841 TB-F-l-0986 ®
COMMUNICA
TELEPHONE TYPE INTERCOM TB-F series
MODELS TB-1F (single-way) TB-3F (three-way)
TB"6F (six-way) TB“12F (twelve-way)
COMMON TALK SELECTIVE RING
- INSTRUCTIONS
NAMES AND FUNCTIONS
Receiver cradle for wall mounting, included
(7) Handset
Station selector buttons
Microphone
Case
Coil cord
(7) Receiver
Terminal cord
(2) Paging button
Terminal box
Directory card
SPECIFICATIONS
* Power source:
Current consumption:
Calling:
Paging:
Wiring:
DC 12 volt. Use PS-12A (PS-12C in North America) AC adaptor. If your system does not in
clude door station or paging system, you may use PS-12S AC adaptor.
70 mA maximum per station.
Push-button station selection. An electronic tone sounds when the selected station button is
depressed.
Use PB-1 paging adaptor in conjunction with standard paging amplifier and speakers.
Up to 17 conductors may be required. Please refer to wiring diagram showing system that
meets your requirements.
BEFORE YOU INSTALL AND OPERATE THE EOUIPMENT
* Operation;
1. DO NOT HOLD HOOK SWITCH DOWN WHILE PICKING UP HANDSET. THE CALL
TONE SOUNDS THRU THE HANDSET RECEIVER ELEMENT AND COULD CAUSE
HEARING DAMAGE.
* Installation;
1. DO NOT CONNECT ANY TERMINAL ON ANY UNIT TO AC POWER LINES.
2. Be sure to remove plug of power supply from AC outlet before you open the unit or make
wiring connections.
3. Avoid running the connecting wires thru doors, windows or between furniture, which may
pinch and disconnectect the wires.
4. The intercom equipment must be installed in as dry and dust-free environment as possible.
* Maintenance;
1. Clean your intercom equipment with a soft cloth dampened with neutral household cleanser.
Never use thinner nor benzine, etc.
2. Do not splash water on the door station by hose, etc.
- 1 -
Prohibitions and precautions -
NEVER
NEVER

Summary of content (8 pages)