Instruction manual

938 Quail Street
Lakewood, CO 80215
primuswindpower.com
PWP Wind Control Panel Manual 2-ARAC-103 RB 3.24.14
Pg.1/5
Wind Control Panel Instruction Manual
(for use with AIR Breeze and AIR 40 12V turbines)
The wind control panel is fully calibrated and ready for installation. Please
follow the instructions below for proper installation.
P/N VOLTAGE CURRENT
2-ARAC-103 12 VDC 25A
OVERVIEW:
The POWER switch is used to turn the wind turbine control panel on and off as well as provide
protection in the case of a major fault. The STOP-RUN toggle switch controls the operation of the
wind turbine. In the RUN position, it allows the wind turbine to operate and produce power while
in the STOP position it places an electric brake on the wind turbine spindle stopping the rotation (in
this mode, slight blade rotation may occur in strong winds). The center position is an OFF position
(disconnecting the wind turbine), but is not recommended. The Ammeter monitors the wind
turbines production.
The wind control panel should be connected to a wind turbine with a current rating equal to or less
than the panel's rating. The Air Breeze and Air 40 units have built-in battery charge regulators. If a
wind turbine is utilized that does not have a built-in regulator, an external diversion load controller
will be necessary to provide proper protection from over charging the battery bank.
Warning
Disconnect battery(s) prior to making connections. Secure the rotor blades of the wind turbine
mechanically so that it is unable to rotate.
MECHANICAL INSTALLATION:
Locate a suitable mounting area for the Wind Control Panel, preferably close to the battery bank
and maintaining the ability to view the meter and operate the controls.
Panel Mount: The panel should be mounted in a clean and dry environment. Be sure the mounting
location is mechanically sound. Allow adequate space behind the panel so that the components will
not touch any surfaces, wires or other items. In the back of this manual you will find a 1:1 cutout
template to assist in installation. Identify your optimum mounting location keeping in mind that