Installation manual

32
CombinationofFHQ18PVJUwithRZR18PVJU,and
FHQ18PVJUwithRZQ18PVJU9,andFHQ24PVJUwith
RZQ24PVJU9qualifyfortheEnergyTaxExtendersof
TheAmericanTaxpayersReliefActof2012.
System Performance
Model Name Indoor (Cooling Only and Heat Pump)
FHQ18PVJU FHQ24PVJU FHQ30PVJU FHQ36MVJU FHQ42MVJU
Outdoor (Cooling Only)
RZR18PVJU RZR24PVJU RZR30PVJU RZR36PVJU RZR42PVJU
Outdoor (Heat Pump)
RZQ18PVJU9 RZQ24PVJU9 RZQ30PVJU RZQ36PVJU9 RZQ42PVJU9
Cooling Capacity (Rated) Btu/h 18,000 24,000 30,000 36,000 40,500
Heating Capacity (Rated) Btu/h 20,000 27,000 34,000 37,500 39,500
SEER 18.0 18.1 17.2 14.0 13.8
EER 14.0 12.6 10.5 10.2 9.5
HSPF* 11.1 10.0 8.4 8.1 8.2
Power Supply V/ph/Hz 208-230/1/60
Minimum Circuit Amps A 16.5 16.5 27 27 27
Maximum Overcurrent Protection A 20 20 30 30 30
Power Consumption - Cooling W 1,290 1,900 2,860 3,530 4,260
Power Consumption - Heating* W 1,510 2,200 3,690 3,660 3,990
Indoor Units - FHQ_PVJU Ceiling Suspended
Model Name FHQ18PVJU FHQ24PVJU FHQ30PVJU FHQ36MVJU FHQ42MVJU
Airflow (H/L) CFM 790/670 790/670 790/670 830/670 850/700
Sound Pressure - Cooling (H/L) dB(A) 45/- 45/- 45/- 46/- 47/-
Sound Pressure - Heating (H/L)* dB(A) 45/- 45/- 45/- 46/- 47/-
Piping Connections
Liquid (O.D.) in. Ø 3/8 Ø 3/8 Ø 3/8 Ø 3/8 Ø 3/8
Gas (O.D.) in. Ø 5/8 Ø 5/8 Ø 5/8 Ø 5/8 Ø 5/8
Condensate Drain in. Ø 1 Ø 1 Ø 1 Ø 1 Ø 1
Dimensions (H x W x D) in. 7-11/16 x 62-5/8 x 26-3/4
Net Weight lbs. 90 90 90 90 90
Outdoor Units - RZR_PVJU Cooling Only and RZQ_PVJU(9) Heat Pump
Model Name
Cooling Only RZR18PVJU RZR24PVJU RZR30PVJU RZR36PVJU RZR42PVJU
Heat Pump RZQ18PVJU9 RZQ24PVJU9 RZQ30PVJU RZQ36PVJU9 RZQ42PVJU9
Sound Pressure Level - Cooling/Heating* dB(A) 49/49 49/49 49/49 58/58 58/58
Operating Range - Cooling °F DB 23 - 115 23 - 115 23 - 115 23 - 115 23 - 115
Operating Range - Cooling with Optional
Wind Baffle
°F DB 0 - 115 0 - 115 0 - 115 0 - 115 0 - 115
Operating Range - Heating* °F DB 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77
Operating Range - Heating* °F WB 0 - 60 0 - 60 0 - 60 0 - 60 0 - 60
Max. Piping Length ft. 164 164 164 230 230
Max. Piping Height ft. 98 98 98 164 164
Dimensions (H x W x D) in. 30-5/16 x 35-7/16 x 12-5/8 52-15/16 x 35-7/16 x 12-5/8
Net Weight lbs. 150 150 150 283 283
*Applicable to heat pump models only
Aslimsolutionforopenorstructuredceilings.
Keyfeaturesinclude:
Sliminheightatlessthan8”
Autoswingcapabilitywith100° airflowpattern
distributescomfortableairflow
Innovativestreamfantechnologykeepssound
pressurelevelslow
Lateralservicingspaceallowsinstallationincorners,
narrowspaces,walls,andceilings
Flatpaneldesignmakescleaningsimple
Concealedpiping
Optional
wiredcontroller
Optionalcondensatepump
CeilingSuspended
RZQ_PVJU(9)
RZR_PVJU
FHQ_PVJU
FHQ_MVJU
BRC1E72
(Option)
BRC7E83
(Option)