VRVIII-S 208-230V Heat Pump
Model Name
RXYMQ36PVJU RXYMQ48PVJU
Performance
Cooling Capacity Btu/h
36,000 47,500
Cooling Input Power kW
Refer to Engineering Data Book
Heating Capacity Btu/hw
42,000 52,500
Heating Input Power kW
Refer to Engineering Data Book
Operating Range - Cooling °F DB
23 - 115 23 - 115
Operating Range - Heating °F DB/°F WB
0 - 64 / -5 - 60 0 - 64 / -5 - 60
Power V/ph/Hz
208-230/1/60 208-230/1/60
Sound Pressure Level @ 3 ft. dB(A)
58 58
Refrigerant Piping
Refrigerant Type and Quantity (lbs.)
R-410A (8.8) R-410A (8.8)
Liquid Pipe (Main Line) in.
3/8 (Flare) 3/8 (Flare)
Suction Gas Pipe (Main Line) in.
5/8 (Flare) 5/8 (Flare)
Vertical Pipe Length ft.
164 164
Actual Pipe Length (Equivalent Length) ft.
492 492
Total Piping Length ft.
984 984
Connection Ratio
Connectable Indoor Unit Ratio %
50 - 130% 50 - 130%
Number of Indoor Units Qty.
68
Unit
Weight lbs.
283 283
Dimensions (H x W x D) in.
52-15/16 x 35-7/16 x 12-5/8
Fan
Airflow cfm
3,740 3,740
Fan Motor Output and Quantity kW (Qty.)
0.07 (2) 0.07 (2)
Electrical
Maximum Overcurrent Protection (MOP) A
30.0 30.0
Minimum Circuit Amps (MCA) A
27.0 27.0
Compressor Rated Load Amps (RLA) A
17.6 23.3
Compressor
Compressor Type
Daikin G-Type Scroll
Compressor Set-Up
1 INV 1 INV
Compressor Capacity Control %
29 - 100 29 - 100
VRVtechnologyinacompactsize.
Features,the7SforSuccess:
Singlephasetechnology
Smallercapacityforprecisetemperaturecontrol
Spacesavingdesignandflexibleindoorunitoptions
offerquickandeasyinstallation
Superiorenergyefficiency,especiallyunderpartload
conditions
Softsoundlevelsforcomfort
Singlesupplierreliability
Straightforwardmaintenanceandservicewith
selfdiagnostic
functions