Use and Care Manual
Table Of Contents
9
Blade Balancing
Check that all blade and blade bracket screws 
are secure.
Most fan wobble problems are caused when 
blade levels are unequal. Check this level by 
selecting a point on the ceiling above the tip of 
one of the blades. Measure from a point on the 
center of each blade to the point on the ceiling. 
Measure this distance as shown in Figure 16. 
Rotate the fan until the next blade is positioned 
for measurement. Repeat for each blade. 
Measurements deviation should be within 1/8˝. 
Run the fan for 10 Minutes.
Use the enclosed Blade Balancing Kit if the 
blade wobble is still noticeable.
1.
2.
3.
The following procedure should correct most fan 
wobble. Check after each step.
Figure 16
Touching Ceiling
Attaching the Switch 
Housing
Remove 1 of 3 screws from the mounting ring 
and loosen the other 2 screws. (Do not remove)
While holding the switch housing under your 
fan, snap together the wire connection plugs.
Place the key holes on the mounting plate over 
the 2 screws previously loosened from the 
mounting ring, turn mounting plate until it 
locks in place at the narrow section of the key 
holes. Secure by tightening the 2 screws 
previously loosened and the one previously 
removed. (Fig. 17)
1.
2.
3.
Figure 17
Mounting Ring
Screws
Switch Housing
Wire Connection
Plugs