Air Force Pro™ Linear Air Pump Oil-Less Compressor Operation & Maintenance Manual IMPORTANT: PLEASE READ THIS MANUAL COMPLETELY. SAVE THIS MANUAL FOR FUTURE REFERENCE AND KEEP IN CLOSE PROXIMITY TO THE AIR PUMP. Models 40 60 80 LINEAR AIR PUMP Oil-Less Compressor Air Force Pro™ Linear Air Pump Operation & Maintenance Manual Oil-Less Compressor Operation & Maintenance Manual IMPORTANT: PLEASE READ THIS MANUAL COMPLETELY.
WARNING ※ IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS ※ TO REPLACE OR CHANGE ANY OF THE PARTS REFERRED IN THE SERVICE MANUAL, WE STRONGLY RECOMMEND YOU CONTACT AN AUTHORIZED TECHNICIAN. DANGER --To avoid possible electric shock, special care should be taken since water is used with or near aquariums and reservoirs.
6) If the plug or outlet does get wet DO NOT UNPLUG THE CORD; Disconnect the fuse or circuit breaker supplying power to the pump, then unplug and examine for the presence of water in the outlet. 7) DO NOT use the pump near volatile liquids such as gasoline, thinners, etc,. as this creates the possibility of an explosion. CAUTIONS FOR USE 1) Close supervision is necessary when an air pump is used by or near children. 2) This pump is intended for clean, dry air only.
SAVE THESE INSTRUCTIONS GROUNDING INSTRUCTIONS 1) For all grounded, cord-connected products: This product must be properly grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
This product must be connected to a grounded, metallic, permanent wiring system, or an equipment-grounding terminal or lead on the product. Power Supply must conform to all required safety codes and be installed by a qualified electrician. Check and Read rating labels listed on product name plate for supply voltage.
Start Up If pump fails to start or slows down significantly under load, shut off and disconnect from power supply. Check that the voltage is correct for the pump. MAINTENANCE Disconnect electrical power supply cord before performing maintenance on this product. Failure to follow these instructions can result in death, fire or electrical shock. Product surfaces may become hot during operation; allow product surfaces to cool before handling. DO NOT direct air stream at body.
Maintenance Manual Maintenance Manual Air Force Pro™ 15 Part No: 746500 IMPORTANT: To open upper enclosure, please make sure you have unplugged the power cord before opening. unplugged before opening 1. To change the diaphragms A. Remove the four screws around the aluminum upper housing, and take the housing off. (As shown in figure 1) B. Remove the four screws from the diaphragm housing. (As shown in figure 2) C. Remove the u-nut in the center of diaphragm. D. Take the diaphragm off its place. E.
Product View and Parts List Product View and Parts list NO.
Product specifications Product Specifications Air Force Pro™ 15 Part No: 746500 +40 -10 . oC < 26 dBA Part No. 746500 20 - 80 2.54 kg Voltage Frequency AMP WATT (VAC) (HZ) (A) (W) 110 ~ 120 60 0.43 20 NOTES: 1. All dimensions are for reference only. 2. Technical data subject to change without notice Performance Allowance ±5% Performance Curves DB15 35 30 Q = L / Min. 25 20 110~120V 60Hz 220~240V 50Hz 15 10 5 0 0 0.05 0.1 0.15 0.2 Pressure = kg / cm2 Dimensions (mm) 9 0.
Maintenance Manual Maintenance Manual Air Force Pro™ 40, 60, 80 Part No: 746505, 746510, 746515 1. To clean the air filter Recommended once every six months A. B. C. D. Remove the screw on top. (As shown in Figure1) Remove filter cover. Take the filter out and clean it with clean water and dry it. Put it back and secure the fixing plate with the screw in. IMPORTANT: To open upper enclosure, please make sure you have unplugged the power cord before opening. 2. To change the diaphragms A.
Product View and Parts List Product View and Parts list Air Force Pro™ 40, 60, 80 Part No: 746505, 746510, 746515 NO.
Product specifications Air Force Pro™ 40 Part No: 746505 Product Specifications +40 40 -20 o C < 46 dBA 20 - 80 6.09 kg Voltage Frequency Part No. 746505 AMP WATT (VAC) (HZ) (A) (W) 110 ~ 120 60 1.1 45 Performance NOTES: 1. All dimensions are for reference only. 2. Technical data subject to change without notice. Allowance ±5% Performance Curves DBM40 80 70 Q = L / Min. 60 50 110~120V 60Hz 220~240V 50Hz 40 30 20 10 0 0 0.05 0.1 0.15 0.2 0.25 0.
Product specifications Product Specifications Air Force Pro™ 60 Part No: 746510 +40 -10 o < 47 dBA C 20 - 80 Voltage Frequency Part No. 746510 60 6.99 kg AMP WATT (VAC) (HZ) (A) (W) 110 ~ 120 60 1.7 63 Performance NOTES: 1. All dimensions are for reference only. 2. Technical data subject to change without notice. Allowance ±5% Performance Curves DBM60 120 Q = L / Min. 100 80 110~120V 60Hz 220~240V 50Hz 60 40 20 0 0 0.05 0.1 0.15 Dimensions (mm) 13 0.2 0.25 0.
Product specifications Air Force Pro™ 80 Part No: 746515 Product Specifications +40 -10 o < 51 dBA C 20 - 80 7.05 kg Voltage Frequency Part No. 746515 AMP WATT (VAC) (HZ) (A) (W) 110 ~ 120 60 1.9 84 80 Performance NOTES: 1. All dimensions are for reference only. 2. Technical data subject to change without notice. Allowance ±5% Performance Curves DBM80 140 120 Q = L / Min. 100 80 110~120V 60Hz 220~240V 50Hz 60 40 20 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.
Limited Warranty Thank you for choosing Air Force Pro™ Linear Air Pumps from Sunlight Supply, Inc. This unit is built to the highest standards using quality materials. To ensure the life and performance of your Air Force Pro™ Linear Air Pump a change of the diaphragm and air filter every year is absolutely necessary for users. Abuse or neglect will void the warranty. TWO-YEAR LIMITED WARRANTY.
Exclusively distributed by: