Use and Care Manual

Operating Instructions
NOTE: Do not operate the humidier without water in the tank.
ON/OFF - Plug in to a standard (120V AC) electrical outlet. The LED Display will turn
on for 2 seconds then turn OFF. Press the ON/OFF button once and the “Operating”
indicator will turn on. Mist will not appear immediately; allow up to 15 minutes for the
water in the tank to transfer to the base.
Delay Start – The Delay Start Feature allows you to program the unit to turn ON
Automatically. Press the “Delay Start” button once; you will see “Delay Start” 01:00H
illuminated on the display. This features works in one hour increments and is program-
mable up to 24 hours. Simply keep pressing the Delay Start button until you get to
your desired delay start time, once you have reached the time the display will ash
three times and then will start to countdown until the unit turns ON.
Auto-Off – The Auto-Off feature allows you to program the unit to turn OFF auto-
matically. Press the “Auto-Off’ button once; you will see “Auto-Off” 01:00 illuminated
on the display. This feature works in one hour increments and is programmable up
to 24 hours. Simply keep pressing the Auto-Off button until you get to your desired
Auto-Off time, once you have reach the time the display will ash three times and
then start to count down until the unit turns OFF. The display will start alternating
between the current ambient humidity and the Auto-off Timer.
NOTE: You can use
the Delay Start and Auto-Off functions together on this fully programmable
LED Display to program the Humidier to turn ON and turn OFF at your
desired times.
LED Dim – To turn OFF the LED Display, press the “LED DIM” button once. Press
the “LED DIM” , or any other button on the control panel to turn the display back ON.
LOW Water – When the Tank is out of water the “waterless” indicator will appear
in the display, you will hear 3 beeps and the automatic safety shut-off will turn the
Ultrasonic Nebulizer & unit OFF.
Mist Output
When you turn the unit ON, it will default to the lowest mist setting. Pressing
the “Mist” button will increase the output. Press once for Medium, twice for High, three times
for Supreme. Pressing the Mist button a fourth time will bring the unit back to Low
.
Humidistat –
By using this feature the humidier will automatically control the humidity
level according to your desired setting. If the set humidity is reached the unit will turn
OFF; if the humidity drops below the setting the unit will turn ON automatically. To set
this feature press the “Humidistat” button to your desired setting. Settings range from
40%-95% RH (Relative Humidity) in 5% RH increments. A 40%-60% Relative Humidity
is recommended. The display will start alternating between the Current and Set ambi-
ent humidity.
1
2
3
6
7
4
5
5