Use & Care Guide

7
7
/
8"
4"
10
7
/
8"
9
3
/
8
"
11"
13
3
/
4"
SPECIFICATIONS
EXHAUST FANS
AK100L
100 CFM/2.5 SONES @ 0.10" WG.
HVI CERTIFIED 120 Volts, 1.5 amps, 60 hz.
Grill
White, polymeric grill secured in place with torsion springs;
easily removed if necessary, dimensions - 11" x 13
3
/
4
". Moonstone
glass lens.
Blower Wheel
Balanced polymeric dual inlet blower wheel 5
1
/
4
" dia. x 2
27
/
32
"
depth, 30 paddles, secured in place via press fit.
Motor
Heavy duty, plug-in, 4 pole motor, life time lubrication, suitable
for continuous operation. Rated 120 volts, 60 hz., 0.80 amps.
Fan Housing
23 gauge galvanized steel housing.
Overall dimensions 10
7
/
8
" x 9
3
/
8
" x 7
7
/
8
".
Duct Collar
Plastic collar for 4" duct connection, comes complete with built
in non-metallic back draft damper for quiet operation.
Ventilating Area
For bathrooms up to 100 sq. ft. For other rooms up to 125 sq. ft.
Electrical Connections
1
/
2
" electrical knockouts provided. Easy wiring access via either
internal or external wiring compartment cover.
CUL/HVI
Canada: 110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015
U.S.: 820 Lincoln Drive
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Updated 5-06Specifications subject to change without notice.
Lamping Information
Main lighting - Up to 100 watt incandescent capacity,
type A19, Medium Base lamp required.
Night lighting -Up to 7 watt incandescent capacity,
type C7, Candelabra Base lamp required.
Unit Mounting
The housing will mount in ceilings with at least 8" of clearance
and through drywall thickness up to
3
/
4
", with a rough-in opening
of 11
1
/
8
" x 9
5
/
8
". Rated for ceilings insulated to R-40. The housing
will mount either between 16" or 24" on center joists, using the
4 supplied housing mounting rails. The housing mounting rails
can be adapted for overhead mounting (hardware not provided).
Single Pack Shipping Info
Box Dim Box Dim: 14
1
/
8
" x 11
5
/
8
" x 12"
UPC: 0-8316221000-5
Shipping Weight: 11.5 lbs.
CUS
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY DATE
FAN MODEL
CFM
IN
RPM WATTS AMPS SONES QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER W.G. & REMARKS
Acceptable for use over tub or shower when
installed in a GFCI protected branch circuit.
PERFORMANCE
HVI Sones Fan Speed Power
Static Pressure (inches of w.g.) @ .1 SP RPM Watts*
0 0.05 0.1 0.125 0.15 0.2 0.25 0.3
Air Flow - CFM
111 108 100 95 90 83 77 72 2.5 1325 42
* Fan power Only – does not include light or night light

Summary of content (1 pages)