Specifications

MEET THE CODE
When fire codes need to be met, Air King’s Fire Rated Series Exhaust Fans are the perfect
solution for multi family wood frame construction.
The Fire Rated Exhaust Fan Series is designed to automatically shut off and seal the duct from
the rest of the dwelling once the temperature of the air passing through the damper exceeds
that of the fusible link.
• ThreepartsystemthatincludesaHousing,Motor/Blade/GrillandDamper
• Availableinsinglepacksorincontractorpacksof4
• Lowproleanddurable,allmetalgrillwithapainted,whitenish
• ULListedforthefollowingWoodFrameConstructionTrussDesigns:
L501 L502 L503 L506 L507 L508 L512 L513 L514 L515
L516 L517 L519 L522 L523 L533 L537 L545 L581 L583
ADVANTAGE 3” DUCT SERIES
• 3”metalductcollarwithbackdraftdamper
• Easilyinstallsusingthedoublethickkeyholemountingtabsor
the included adjustable hanging brackets
• Availableincontractorpacks
• Recommended Controls: AKEDT1
ADVANTAGE 4” DUCT SERIES
• 4”metalductcollarwithbackdraftdamper
• Easilyinstallsusingtheincludedadjustablehangingbrackets
• Availableincontractorpacks
• Recommended Controls: AKEDT1
QUIET SERIES
• QuietOperation
• 4”metalductcollarwithbackdraftdamper
• Easilyinstallsusingtheincludedadjustablehangingbrackets
• Availableincontractorpacks
• Recommended Controls: AKEDT1
19
AMCA
2
HVI
2
ENERGY DUCT HOUSING
MODEL CFM/SONES SONES AMPS MOTOR HOUSING DAMPER STAR SIZE SIZE
FRAS50 47/4.0 3.0 .57 FA50T AKFH1 AKFD1 NO 3" 7
3
/
8
"W x 7
5
/
8
"D x 5
7
/
8
"H
FRAS60 60/5.7 4.5 .57 FA60T AKFH1 AKFD1 NO 3" 7
3
/
8
"W x 7
5
/
8
"D x 5
7
/
8
"H
FRAS70 66/6.9 5.0 1.20 FA70T AKFH1 AKFD1 NO 3" 7
3
/
8
"W x 7
5
/
8
"D x 5
7
/
8
"H
FRAS90 90/3.1 2.5 .45 FA90T AKFH2 AKFD2 NO 4" 10
3
/
4
"W x 9
1
/
4
"D x 7
7
/
8
"H
FRAS120 120/3.7 4.0 .80 FA120T AKFH2 AKFD2 NO 4" 10
3
/
4
"W x 9
1
/
4
"D x 7
7
/
8
"H
FRAK80 80/2.6 1.5 .30 FAK80T AKFH2 AKFD2 YES 4" 10
3
/
4
"W x 9
1
/
4
"D x 7
7
/
8
"H
FRAK90 90/2.9 1.5 .31 FAK90T AKFH2 AKFD2 YES 4" 10
3
/
4
"W x 9
1
/
4
"D x 7
7
/
8
"H
FRAK110 110/3.5 2.0 .45 FAK110T AKFH2 AKFD2 NO 4" 10
3
/
4
"W x 9
1
/
4
"D x 7
7
/
8
"H
Air King Ventilation Products certifies that the models
shown herein are licensed to bear the AMCA seal.
The ratings shown are based on tests and procedures
performed in accordance with AMCA Publication
211 and AMCA Publication 311 and comply with the
requirements of the Certified Ratings Program.
2
Recorded at 0.1 WG
Performance shown is for FRAK exhaust models for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet
grille, ceiling radiation damper and back draft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test.
The loudness ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA standard 301. Values
shownareforinstallationtypeB:freeinletfansonelevels.•Specicationssubjecttochange.