Ventilation Air Requirements, cfm
Floor Area Bedrooms
(ft
2
) 0-1 2-3 4-5 6-7 >7
<1500 30 45 60 75 90
1501-3000 45 60 75 90 105
3001-4500 60 75 90 105 120
4501-6000 75 90 105 120 135
6001-7500 90 105 120 135 150
>7500 105 120 135 150 165
6
www.airkinglimited.com
ECO-EXHAUST SINGLE SPEED SERIES
The ENERGY STAR
®
Eco-Exhaust Fan Series provides solutions for areas needing higher
volume ventilation that operates at barely audible sound levels, is cost effective, and energy
efficient. The series features a low profile grill that almost disappears into the ceiling and
a motor with a large, quiet, centrifugal blower wheel that assures proper ventilation with
minimum sound.
• Models: ES80S, ES130S
• LowestpossibleHVIcertiedsoundrating-Lessthan0.3Sones!
• Easilyinstallsusingtheincludedadjustablehangingbrackets
• Motorssuitableforcontinuousoperationandtheextremelylowsoundlevelsmake
them perfect for this application
• SuitableforusewithElectronicFanSpeedControl
• 6"roundductconnectorwithspringloadedmetaldamperprotectsagainstbackdrafts
• ListedforinstallationoveratuborshoweronaGFCIcircuit
• Sideaccesspanelallowsyoutowirethefanfrominsideoroutsidethehousing
ASHRAE 62.2
Ashrae 62.2 is a minimum national standard that provides methods for achieving acceptable
indoor air quality in typical residences. The standard has three main components; Source
Control – preventing or limiting the introduction of pollutants, Local Exhaust –removing high
concentrations of contaminants in the rooms where they occur (kitchens and bathrooms), and
Whole House Ventilation – diluting the air in the main living spaces to remove unavoidable
contaminants from people, pets, cleaning, offgassing, etc.
The standard provides many alternative methods for good design as well as requirements
for extreme environments, high density occupancies, and other special situations. For
most common applications Air King recommends the installation of an ENERGY STAR
®
Qualified Eco-Exhaust fan in a central area of the home such as an upstairs hallway. This
fan provides practically silent (less than 0.3 sones) whole house ventilation. For local exhaust
in the bathroom install ENERGY STAR
®
Qualified BFQ50 or BFQ75 models with an AKEDT1
control to automatically turnoff the fan after selected time period (20, 40 or 60 minutes). In the
kitchen install an ENERGY STAR
®
Qualified Air King Range Hood.
ENERGY DUCT CONTINUOUS TUB/SHOWER
1
HOUSING
MODEL CFM/SONES STAR
®
SIZE OPERATION LISTED SIZE
ES80S 80/<0.3 YES 6" YES YES 12
7
/
8
"W x 12
3
/
4
"D x 9
7
/
8
"H
ES130S 130/<0.3 YES 6" YES YES 12
7
/
8
"W x 12
3
/
4
"D x 9
7
/
8
"H
1
ETLListedforuseovertuborshowerwheninstalledinaGFCIprotectedbranchcircuit.•Specicationssubjecttochange.
FIRST FLOOR
SECOND FLOOR
Bedroom 3Bedroom 2
Master Bath
Closet
Bath
Master
Bedroom
Bedroom 4
Open
Kitchen
Family Room
Powder Room
Laundry
Ofce
Foyer
Dining
Room
Garage
Ideal for Air King model ES80S
Ideal for Air King model ES130S
Table is a duplication of Table 4.1a (I-P) for Minimum Ventilation from
the ANSI/ASHRAE Standard 62.2-2007 for Ventilation and Acceptable
Indoor Air Quality in Low-Rise Residential Buildings. Highlighting has
been added to the table to show Air King's model recommendations.
Air King recommendations are to provide a simple, easy, and effective
way to comply with the Ashrae standard in most typical situations. See
Ashrae 62.2 2007 for special situations and additional requirements that
may apply as well as limitations.
Model BFQ50 or BFQ75
for local exhaust
Model BFQ50 or BFQ75
for local exhaust
Model BFQ50 or BFQ75
for local exhaust
Model ES80S or ES130S for
continuous whole house ventilation
Continuous Ventilation
LOWESTLOWEST
HVI SOUND
RATING POSSIBLE
HVI SOUND