Instruction Sheet

INSTALLATION INSTRUCTIONS
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
WARNING: TO REDUCE THE RISK OF FIRE, DO NOT STORE
OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINITY OF THE HEATER.
SECTION 1
Preparing the Exhaust Fan
1. Unpack fan from the carton and confirm that all pieces are present. In addition to the
exhaust fan you should have:
1 - Grill
1 - Damper Assembly (attached)
4 - Mounting Rails
1 - Instruction/Safety Sheet
2. Remove the wire compartment cover by loosening the two screws holding the cover in
place (Figure 1).
3. Choose the location for your fan. To ensure the best air and sound performance, it is
recommended that the length of ducting and the number of elbows be kept to a
minimum, and that insulated hard ducting be used.
Larger duct sizes will reduce noise and airflow
restrictions. This fan will require at least 8" of
clearance in the ceiling or wall, and will mount
through drywall up to 3/4" thick. The fan mounts
between 16” on center joists using the provided
mounting rails.
3. Select the most convenient electrical knockout and
remove using a straight-blade screw driver (Figure 2).
SECTION 2
New Construction
1. Install the rails on the housing and position the housing next to the joist. Line up housing
so that it will be flush with the finished ceiling. Secure the ends of the rails with screws
or nails (not included) to the joists and slide the housing into the final position (Figure 3).
SECTION 3
Existing Construction
1. Set housing in position between the joist and trace an outline onto the ceiling material
(Figure 4). Set housing aside and cut opening, being careful not to cut or damage any
electrical or other hidden utilities. Install the rails on the housing and position the housing
in the previously cut hole so that it is flush with the finished ceiling. Secure the ends of
the rails to the joists (Figure 3).
www.airkinglimited.com
210575917 Rev. F 12-15 2 of 8
SECTION 4
Ducting
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL
BUILDING CODES.
1. Remove any tape that might be holding the damper in place during shipping and connect
the ducting to the fan’s duct collar (Figure 5). Secure in place using tape or screw
clamp. Always duct the fan to the outside through a wall or roof cap.
SECTION 5
Wiring
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE
MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR
NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING
ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
NOTE: This unit includes a side access panel for wiring that does not require the removal of the
fan’s blower assembly. If you choose to wire the unit from the inside, you will need to remove the
blower assembly and internal wiring compartment. Both methods are equally effective.
1a. Wiring Fan/Heat Bulb(s) Independently: Run wiring from an approved wall switch
carrying the appropriate rating. One neutral (white), one ground (green or bare copper),
and two hot (black and blue). Secure the electrical wires to the housing with an approved
electrical connector. Make sure you leave enough wiring in the box to make the
connection to the fan’s receptacle.
1b. From where you have access to inside the fan’s junction box, connect the white wire
from the house to the white wire from the fan. Connect one hot (black) wire from the
house to the black wire from the fan (this is the fan control). Connect the second hot
(blue) wire from the house to the blue wire from the fan (this is the heat bulb control).
Connect the ground wire from the house to the green wire from the fan (Figure 6). Use
approved methods for all connections.
NOTE: On model AK927 connect the Hot (Blue) wire from the house to the two Blue wires from
the unit.
Housing
Joist
Mounting Rails
Figure 3
Figure 2
Figure 1
Screws
Wire
Compartment
Cover
Figure 4
Figure 5
Figure 6
Hot (Black)
Hot (Blue)
White
Ground
From Fan
Supply from house