Operating instructions

IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock and injury to person, including the following:
SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this heater only as described in this manual. Any other use not recommended
by the manufacturer may cause fire, electric shock, or injury to persons.
b) Operate heater only when grille is installed.
c) Before servicing or cleaning the unit, switch power off at service panel and
lock the service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
d) Do not operate any heater after it malfunctions. Disconnect power at service
panel and have heater inspected by a reputable electrician before reusing.
e) Do not use outdoors.
f) Do not insert or allow foreign objects to enter any ventilation or exhaust
opening as this may cause and electric shock or fire, or damage the heater.
g) To prevent a possible fire, do not block air intakes or exhaust in any manner.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards, including fire-related
construction.
b) For supply connections, use wires suitable for at least 75° C (167° F).
c) Use copper wire only.
d) Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent back drafting. Follow
the heating equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association (NFPA) and the
American Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
e) When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
f) A heater has hot and arcing or sparking parts inside. Do not use in areas where
gasoline, paint, or flammable vapors or liquids are used or stored.
g) Ducted fans must always be vented to the outdoors.
h) This unit must be grounded.
i) To avoid motor bearing damage and noisy and/or unbalanced impellers, keep
drywall spray, construction dust, etc. off power unit.
j) This heater is hot when in use. To avoid burns, do not let bare skin touch hot
surfaces.
k) Extreme caution is necessary when any heater is used by or near children or
invalids and whenever the heater is left operating and unattended.
IMPORTANT INSTRUCTIONS: Read all instructions before installing or using
exhaust fan.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT
USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING: DO NOT INSTALL OVER A TUB OR MOUNT IN A SHOWER
STALL ENCLOSURE.
WARNING: DO NOT USE IN KITCHENS.
WARNING: THIS UNIT IS DESIGNED AND TESTED TO BE A
SUPPLEMENTAL HEATER FOR USE WITH A TIMER OR A SWITCH. IT IS NOT
INTENDED TO BE USED AS THE PRIMARY SOURCE OF HEAT AND CONTROLLED
BY A THERMOSTAT.
Motor is thermally protected.
Electrical Ratings: AK965 - 120V, 60Hz., 15.65A
AKF965 - 120V, 60Hz., 15.20A
www.airkinglimited.com
965 Rev. D 5-14 1 of 12
Exhaust Fan with Heater
Models: AK965, AKF965

Summary of content (12 pages)