Installation Sheet

SECTION 4
Blower Installation for Ducted
Range Hoods
NOTE: When reinstalling the blower, ensure
that the blower is facing the same way as
how you have chosen to duct it.
NOTE: Makes sure to support the blower in
position by hand until it is firmly secured to
the hood.
NOTE: FOR DUCTLESS INSTALLATIONS
ONLY, if you did not already do so in the
earlier steps, remove the vent block-off plate
from under the top of the hood (Figure 4).
1. With the opening of the blower facing
the direction you have chosen to duct
the hood, place the blower mounting
brackets (brackets on either side of the
blower) over the blower mounting studs
on the interior of the hood (Figure 6).
2. Using the 4 nuts removed earlier, secure
the blower in place. Start the nuts by
hand first, then tighten with a 3/8" nut
driver or ratchet until they are fully
seated (Figure 6).
3. Plug the blower connector into the
port on the front wall of the blower
compartment. It will fit only one way
(Figure 7).
www.airkinglimited.com
5085462 New 2-12 3 of 12
SECTION 6
Wiring
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE
WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE
UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE
SERVICES OF A QUALIFIED ELECTRICIAN.
1. Connect the loose White wire from the range hood to the White wire from the supply,
and the loose Black wire from the range hood to the Black wire of the supply. Connect
the ground wire (green or bare) from the supply to the green wire from the hood. Use
approved methods for all connections (Figure 9).
2. Install the wire compartment cover by reversing the instructions is Section 1, Step 3.
Make sure all wiring is securely contained within the wire compartment and the nut is
fully tightened.
SECTION 7
Ducting
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL
BUILDING CODES.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
1. Connect the ducting to the hood’s duct collar and damper. Secure in place using tape to
seal all joints (Figure 10).
CAUTION: ALWAYS DUCT THE FAN TO THE OUTSIDE THROUGH A WALL OR
ROOF CAP.
SECTION 5
Installing the Range Hood
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL
BEFORE STARTING INSTALLATION.
NOTE: If installing into existing construction and you will not have access to the ductwork
once the hood is in place, make ducting connections at this point. Refer to the Ducting
Section for instructions.
1. Install the 4 mounting screws at the previously marked locations. Leave
approximately 1/8" clearance. Slide the hood in place through the keyhole slots and
align the front of the hood so that it is flush with the front of the cabinets. Tighten all
screws securely (Figure 8).
Keyhole
1/8"
Figure 8
Figure 7
Figure 9
Neutral
(White)
From Hood
Hot (Black)
Ground (Green or Bare)
From Hood
Figure 10
From Hood
Studs
Figure 6
Vertical
Ductless
Horizontal
Studs
Studs
Connector
Fuse