Installation Sheet

INSTALLATION INSTRUCTIONS
CAUTION:
MAKE SURE POWER IS SWITCHED OFF
AT SERVICE PANEL BEFORE STARTING INSTALLATION.
WARNING: THIS BLOWER IS INTENDED FOR USE ONLY
IN AIR KING PROFESSIONAL SERIES RANGEHOOD CANOPIES
MARKED SUITABLE FOR USE WITH THIS BLOWER. DO NOT INSTALL IN
ANY OTHER APPLICATION.
SECTION 1
Preparing for installation
NOTE: Before installing blower, make sure range hood canopy is properly
installed and securely in place. See “Range Hood Mounting Instructions”.
1. Unpack blower from the carton and confirm that all pieces are present.
In addition to the blower you should have:
10 - #8-32 Screws
8 - Flat Washers
8 - Star Washers
1 - Capacitor Box
2 - #6 Screws
1 - Transformer
1 - Fuse
1 - Instruction/Safety Sheet
2. Attach the capacitor to the blower by lining up the two holes on the flange of
the capacitor with the holes on the blower. Use the 2 included #6 screws to
make the connection and fully tighten (Figure 1).
3. The installation of the blower is slightly different from one canopy
height to another. For 18" high canopies proceed to Section 2, for 10"
high canopies proceed to Section 3.
SECTION 2
Installation into 18" High Canopy
1. Install transformer into hood canopy by lining up the 2 holes on the
flange of the transformer with the 2 screw studs in the top left side
of the hood canopy. Use 2 of the included #8-32 screws to make the
connection and fully tighten (Figure 2).
www.airkinglimited.com
672018 Rev. i 12-18 2 of 8
2. Loosely install the two #10-32 serrated flange nuts (included) onto the
studs located inside the top center of the hood.
3. Lift blower up into the hood canopy and slide the keyhole slots in
the blower mounting flange over the two studs of the hood. Slide the
blower into place and tighten the hex nuts on the mounting stud while
lining up the 8 holes in the blower mounting flange to the 8 screw
studs of the hood (Figure 3).
4. Using 8 of the included #8-32 screws, flat washers and star washers,
mount the blower in place and tighten all screws. Confirm that the
blower is securely seated in place and there are no air gaps around the
blower gasket.
5. Plug the 3 wire quick connect cord from the blower into the receptacle
on the range hood canopy. Plug the 4 wire quick connect cord from the
blower into the receptacle on the transformer. Plug the 2 wire quick
connect from the transformer into the receptacle on the range hood
canopy. Plug the 4 wire quick connect from the transformer into the
receptacle on the range hood canopy. These cords will only fit into the
receptacles one way (Figure 4).
SECTION 3
Installation into 10” High Canopy
1. Remove the rear bottom plate of the hood canopy. It is secured in place
with a nut and washer on either side (Figure 5).
Figure 3
Stud w/Hex Nuts
Screw Stud
Keyholes
Transformer
Rear Wall
Figure 2
Figure 1
Figure 5
Nut
Washer
Bottom Plate
Receptacles
Blower
Transformer
Figure 4