Specification Sheet

SPECIFICATIONS
EXHAUST FAN
ES130DH
Updated 7-12Specifications subject to change without notice.
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY DATE
FAN MODEL
CFM
IN
RPM
WATTS AMPS SONES QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER W.G. & REMARKS
Acceptable for use over
tub or shower when
installed in a GFCI
protected branch circuit.
130 CFM/<0.3 Sones @ 0.10" SP., 32.5 Watts
93 CFM @ 0.25 SP.
50 CFM/<0.3 Sones @ 0.10" SP., 26.9 Watts
EXPANDED PERFORMANCE
Sones Sones Fan Speed Power
Static Pressure (inches of w.g.) @ .1 SP @ .25 SP RPM Watts Amps
0 0.1 0.15 0.2 0.25 0.3 0.35
Air Flow - CFM (High Speed) 149 130 119 107 93 79 62 <0.3 <0.3 783 32.5 0.30
Air Flow - CFM (Low Speed) 81 50 33 16 - - - <0.3 <0.3 715 26.9 0.30
Grill
White, polymeric grill secured in place with torsion springs; easily
removed if necessary, dimensions - 14
1
/
4
" x 14
1
/
4
".
Blower Wheel
Balanced polymeric dual inlet blower wheel secured in place using a
hex nut.
Motor
Enclosed 4 pole high efficiency, permanently split capacitor motor
(PSC); life time lubrication, suitable for continuous operation. Motor
bearings - sleeve. Rated 115/120 volts, 60 Hz.
Fan Housing
23 gauge galvanized steel housing. Overall dimensions:
12
7
/
8
"x 12
3
/
4
"x 9
7
/
8
".
Humidity Sensor
Integrated humidity sensor, adjustable up to 80% RH automatically
turns fan on until the humidity drops to the desired set point.
Duct Collar
6" round, zinc plated metal collar adapter. 6" spring loaded
aluminum backdraft damper.
Electrical Connections
.5" electrical knockouts provided. Easy wiring access via either
internal or external wiring compartment cover.
Single Pack Shipping Info
Box Dim: 20" x 15
7
/
8
" x 11
3
/
8
"
Shipping Weight: 17 lbs.
Unit Mounting
The housing will mount through drywall thickness up to
3
/
4
", with a
rough-in opening of 13
1
/
8
" x 13". Rated for ceilings insulated to
R-40. The housing will mount either between 16" or 24" on center
joists, using the 2 supplied housing mounting brackets. The housing
mounting brackets can be adapted for overhead mounting (hardware
not provided). The unit is provided with an optionally installed ceiling
flange to ensure proper building infiltration rates are maintained and
that no air leaks occur between the fan housing and ceiling cutout.
Canada: 8 Edvac Drive
Brampton, Ontario L6S 5P2
Tel: (905) 456-2033 • 800-250-8767
Fax: (905) 456-1015
U.S.: 820 Lincoln Avenue
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
M
E
E
T
S
M
A
D
E
I
N
A
M
E
R
I
C
A
R
E
Q
U
I
R
E
M
E
N
T
S
O
F
A
R
R
A
M
E
E
T
S
M
A
D
E
I
N
A
M
E
R
I
C
A
R
E
Q
U
I
R
E
M
E
N
T
S
O
F
A
R
R
A
12
7
/
8
"
12
3
/
4
"
6"
9
7
/
8
"
14
1
/
4
"
14
1
/
4
"

Summary of content (1 pages)