Specification Sheet

SPECIFICATIONS
EXHAUST FAN
EL80SGH
Specifications subject to change without notice.
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY DATE
FAN MODEL
CFM
IN
RPM
WATTS AMPS SONES QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER W.G. & REMARKS
Grill
White, polymeric grill secured in place with torsion springs; easily
removed if necessary, dimensions - 17" x 15
7
/
8
".
Blower Wheel
Balanced polymeric dual inlet blower wheel secured in place using a
hex nut.
Motor
Enclosed 4 pole high efficiency, permanently split capacitor motor
(PSC); life time lubrication, suitable for continuous operation. Rated
115/120 volts, 60 Hz.
Fan Housing
23 gauge galvanized steel housing. Fan housing dimensions:
12
7
/
8
"x 12
3
/
4
"x 9
7
/
8
".
Motion Sensor
Integrated motion sensor automatically turns fan to high speed when
room is occupied. Adjustable off delay from 30 seconds to 80 minutes.
Humidity Sensor
Integrated humidity sensor, adjustable up to 80% RH automatically
turns fan to on until humidity drops to the desired set point.
Duct Collar
6" round, zinc plated metal collar adapter. 6" spring loaded and
gasketed aluminum backdraft damper.
Electrical Connections
0.5" electrical knockouts provided. Easy wiring access via either
internal or external wiring compartment cover.
Lighting
GU24 base, 8 Watt 4000K LED Lamp, 725 Lumens (91 Lumens/Watt)
4 watt night light (night light bulb not included).
Unit Mounting
The housing will mount through drywall thickness up to
3
/
4
", with a
rough-in opening of 13
1
/
8
" x 13". The housing will mount either
between 16" or 24" on center joists, using the 2 supplied housing
mounting brackets. The housing mounting brackets can be adapted
for overhead mounting (hardware not provided). The unit is provided
with an optionally installed ceiling flange to ensure proper building
infiltration rates are maintained and that no air leaks occur between
the fan housing and ceiling cutout.
Acceptable for use over
tub or shower when
installed in a GFCI
protected branch circuit.
12
7
/
8
"
12
3
/
4
"
9
7
/
8
"
17"
15
7
/
8
"
6"
80 CFM/<0.3 Sones @ 0.10" SP.
82 CFM @ 0.25 SP. (Boost)
EXPANDED PERFORMANCE
Sones Fan Speed Maximum Full Load
Static Pressure (inches of w.g.) @ .1 SP RPM Fan Watts Amps
0 0.05 0.1 0.15 0.20 0.25* 0.375
Air Flow - CFM 101 90 80 70 59 49/82 5 <0.3 843 37.0 0.7
* Boost speed provides 82 CFM @ .25 Static Pressure, 0.6 sones
M
E
E
T
S
M
A
D
E
I
N
A
M
E
R
I
C
A
R
E
Q
U
I
R
E
M
E
N
T
S
O
F
A
R
R
A
M
E
E
T
S
M
A
D
E
I
N
A
M
E
R
I
C
A
R
E
Q
U
I
R
E
M
E
N
T
S
O
F
A
R
R
A
Updated 9-16
Canada:
Brampton, Ontario
Tel: 800-250-8767
Fax: (905) 456-1015
U.S.: 820 Lincoln Avenue
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048

Summary of content (1 pages)