Spec Sheet

SPECIFICATIONS
EXHAUST FAN
FRAK100
Specifications subject to change without notice.
Grill
Cold rolled steel, powder coated white.
Blower Wheel
One piece polymeric centrifugal blower wheel, 5
1
/
4
" diameter, 2
7
/
8
"
wide, with 30 paddles.
Motor
Heavy duty, permanently split capacitor, 4 pole motor, life time
lubrication, thermally protected, suitable for continuous operation.
Rated 120 volts.
Contractor Pack (Motor/BladeGrill) Model: FAK100T*
Fan Housing
24 gauge galvanized steel housing, dimensions 10
3
/
4
" x 9
1
/
4
" x 7
7
/
8
".
Contractor Pack Model: AKFH2*
Duct Collar
Metal collar for 4" duct connection, comes complete with built in
back draft damper.
Damper
Blanket - Non-asbestos, ceramic blanket
Fusible Link - Replaceable, 165°F standard
Classification - CUL Listed 555C and 263. California State Marshall
classification for 3 hour fire damper rating. California State Marshall
listing number 3226-1721:0109.
Contractor Pack Model: AKFD2*
Unit Mounting
FRAK100 is centered between joists (with 16" centers) using
hanging brackets. The housing will mount through drywall thickness
up to
3
/
4
", with a rough-in opening of 10
3
/
4
" x 9
1
/
4
".
* Sold in packs of 4. All three parts
(housing, damper, motor/blade/grill) must
be purchased and used together to make a complete unit.
Ventilating Area
For bathrooms up to 100 sq. ft. For other rooms up to 125 sq. ft.
Wood Frame Truss Design Listings
ETL Classified UL263/E119:
L501, L502, L503, L506, L507, L508, L512, L513,
L514, L515, L516, L517, L519, L521, L522, L523,
L528, L530, L533, L537, L545, L546, L550, L562,
L563,L570, L574, L579, L581, L583, L585, L586,
M503, M530, M538, P522, P531, P538, P545, P552
cULus: L501, L502, L503, L506, L507, L508, L512, L513,
L514, L515, L516, L517, L519, L522, L523, L533,
L537, L545, L581, L583, M530, M538
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY DATE
FAN MODEL
CFM
IN
RPM
WATTS AMPS SONES QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER W.G. & REMARKS
Acceptable for use over
tub or shower when
installed in a GFCI
protected branch circuit.
100 CFM/2.0 Sones @ 0.10" SP.
82 CFM @ 0.25 SP.
EXPANDED PERFORMANCE
Sones Fan Speed Maximum
Static Pressure (inches of w.g.) @ .1 SP RPM Fan Watts Amps
0 0.05 0.1 0.125 0.15 0.2 0.25
Air Flow - CFM 108 104 100 99 97 93 82 2.0 1177 27.5 0.30
V
E
N
T
I
L
A
T
I
O
N
S
T
A
N
D
A
R
D
S
62.2
ASHRAE
COMPLIES WITH
Air King: 820 Lincoln Avenue
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Updated 10-19
Canada:
Brampton, Ontario
Tel: 905-456-2033
Fax: (905) 456-1015
9
1
/
4
"
10
3
/
4
"
7
7
/
8
"
4"
5
/
8
"
12
15
/
16
"
10
5
/
16
"
M
E
E
T
S
M
A
D
E
I
N
A
M
E
R
I
C
A
R
E
Q
U
I
R
E
M
E
N
T
S
O
F
A
R
R
A
M
E
E
T
S
M
A
D
E
I
N
A
M
E
R
I
C
A
R
E
Q
U
I
R
E
M
E
N
T
S
O
F
A
R
R
A

Summary of content (1 pages)