PLEASE READ AND SAVE ALL INSTRUCTIONS! LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS! ¡POR FAVOR LEA Y GUARDE TODAS LAS INSTRUCCIONES! AOS 2055A
en Instructions for use (5 – 18) Instructions d’utilisation (19 – 32) a Instrucciones para el uso (33 – 46) a es 3 fr
en Instructions for use 5
en PLEASE READ AND SAVE ALL THESE INSTRUCTIONS! Important safety instructions • Prior to using the appliance, read through the in structions for complete use and retain in a safe place for later reference. • WARNING – Only use the appliance indoors and within the specified technical data. Improper use can be hazardous for the health and lead to critical injury. • Connect the unit only to alternating current with voltage according to the rating label.
1 4 7 2 5 8 3 6 9 en 7
en Foreword Congratulations on purchasing the AIR-O-SWISS 2055A Air Washer! Did you know that excessively dry indoor air • dries out mucus membranes and causes chapped lips and stinging eyes? • promotes infections and diseases of the respiratory tract? • leads to weariness, tiredness and poor concentration? • is a burden on pets and house plants? • promotes the formation of dust and increases the elec trostatic charge of textiles made from synthetic fibers, carpets and synthetic floors? • damages furnishi
13 Description of the appliance Air inlet Cover Control panel 14 Air outlet Putting into operation The best location for your appliance is: • On the floor, or on a level, dry surface in the room. • Pay proper attention to easy accessibility and sufficient space for servicing and cleaning the unit. • Read the section «Filling the tank» on how to fill the water tank (16 – 20). • Place the water tank on the lower part (20).
en Filling the tank Always unplug the unit before removing the water tank. Do not operate the appliance when the water tank is empty! 16 17 18 Only fill the water tank with fresh, cold tap wa ter. Use water additives at your own risk. We do no accept any liability for possible reductions in performance or damage. Do not put the water tank under pressure, e.g. by filling with carbonated mineral water.
Operating AOS 2055A B C D) Night mode D E en If you turn the rotary dial to position D, the appliance works in night mode and is especially quiet. E) Operating light and Automatic Shut-Off «Tank empty» The green light (LED) (E) illuminates when the appliance is switched on. The water level is easy to see thanks to the transparent water tank. The red LED light on the appliance also shows when the unit should be refilled with water.
en Water quality maintenance The AIR-O-SWISS Hydro Stick 7017 keeps AIR-O-SWISS humidifiers operating at their highest level between recommended cleanings*. Good for one year, the Hydro Stick ensures the humidifier’s functionality while providing fresh humidification performance. It starts to work as soon as it comes in to contact with water, even if the unit is turned off. The Hydro Stick should be changed every year. Look at picture 22 for the posi tion of the Hydro Stick in the base part of the unit.
24 27 30 25 28 31 en 3 AC ID 26 29 1 2 32 13
en Cleaning the water tank and base (every 2 weeks) • Lift the water tank out of the unit, open the water tank cap and clean the tank (33 – 35). • Lift the upper part of the unit off the base and remove the Ionic Silver Stick® (36). • Use AIR-O-SWISS EZCal custom cleaning and descaling agent only to remove deposits from the water base re gularly (37). There is a sample of EZCal included in the packaging of your humidifier. Instructions for using are on the packet.
37 40 43 38 41 44 39 42 45 en 30 min 140°F / 60°C 15
en Storing the appliance for extended periods Clean the appliance as described earlier and allow to dry thoroughly. Preferably store the appliance in its original box, in a dry place away from high temperatures. Legal notice The humidifier is cUL-listed. Subject to technical change. The instructions for use are protected by copyright © PLASTON AG. Accessories Contact your local retailer or check our website www. airoswiss.net for re-order information.
General Humidifier Questions Q. Why isn’t there enough moisture in my room? A. How often do you run the unit? If the unit is only run at night, then during the day the moisture level will drop if moisture is not constantly added to the air. A. Do you leave your door open or closed when the unit is running? a. By leaving the door open, this allows moisture to leave the room and go into other areas of the house.
en Q. Is it ok to put my humidifying discs in the dishwasher? A. The manufacturer of this appliance does NOT recom mend it. The plates can only be placed in a dishwasher where the temperature is no greater than 131°F / 55ºC. If the temperature is any hotter than this, the plates will melt. Place the plates in a sink filled with warm water and white vinegar or EZCal and either let them soak or spin the plates in this solution.
AIR-O-SWISS is a registered trademark of PLASTON Group, Switzerland 36130-01 Please check our website www.airoswiss.net for further information.