Energy Guide

Climates with Outdoor Humidity Levels of 70% Rh
* Actual requirements may vary.
Dehumidifier Capacity Required
to Maintain Desired Indoor Rh*
60% Indoor Rh 55% Indoor Rh 50% Indoor Rh
Area size
(square feet)
Pints/Day Pints/Day Pints/Day
2,000 47 53 68
2,500 59 66 85
3,000 71 79 102
3,500 82 93 119
Climates with Outdoor Humidity Levels of 80% Rh
Dehumidifier Capacity Required
to Maintain Desired Indoor Rh*
60% Indoor Rh 55% Indoor Rh 50% Indoor Rh
Area size
(square feet)
Pints/Day Pints/Day Pints/Day
2,000 50 54 72
2,500 62 68 90
3,000 74 81 107
3,500 87 95 125
Climates with Outdoor Humidity Levels of 90% Rh
Dehumidifier Capacity Required to
Maintain Desired Indoor Rh*
60% Indoor Rh 55% Indoor Rh 50% Indoor Rh
Area size
(square feet)
Pints/Day Pints/Day Pints/Day
2,000 52 56 75
2,500 65 70 94
3,000 78 84 113
3,500 91 98 131
August 2007