User's Manual
Table Of Contents
- Product Manual
- And Installation Guide
- Introduction
- Hardware Description
- Backhaul / Point-to-point Architecture
- Multipoint Architecture
- Repeater Architecture
- Mesh Architecture
- System Requirements
- Hardware Installation
- Installing and Visually Aligning Outdoor Units
- Software Configuration
- Getting Started
- Logging into the WirelessGRID NMS
- Current Settings
- Wired Network Settings
- Radio Network Settings
- WirelessGRID Bridge List
- WirelessGRID System Setup Tab
- Network Settings Tab
- Radio Settings Tab
- Admin Setup Tab
- Security Tab – Data Encryption
- WirelessGRID Authentication
- Data Encryption
- Encryption Key Manager
- Security Server (RADIUS) Settings
- Active Bridge Status Tab
- Remote Bridge (SU Station) Statistics Tab
- Firmware Update Tab
- Help Tab
- Antenna alignment and link monitoring tool
- Using the real-time signal strength monitor for antenna alignment
- Antenna Adjustment Using the real-time Signal Strength Monitor
- Specifications
- _
- _
- 4.940-4.990 GHz Public Safety Band (FCC Part 70, licensed Intl.)Non-overlapping Channels: 8 x 5 MHz, 4 x 10 MHz, 2 x 20 MHz, 1 x 40 MHz
- 5.25-5.35 GHz license-exempt (FCC, Industry Canada, Mexico)Non-overlapping Channels: 19 x 5 MHz, 9 x 10 MHz, 4 x 20 MHz, 2 x 40 MHz
- 5.47-5.72 GHz license-exempt (ETSI, FCC, ITU) with TPC and DFSNon-overlapping Channels: 44 x 5 MHz, 22 x 10 MHz, 11 x 20 MHz, 5 x 40 MHz
- 5.725-5.850 GHz licence exempt UNII & ISM Bands (ETSI, FCC, MII) Non-overlapping Channels: ISM, UNII: 25 x 5 MHz, 12 x 10 MHz, 5 x 20 MHz, 2 x 40 MHz
- Orthogonal Frequency Division Multiplexing (OFDM)
- 802.3, 802.11i draft, 802.11a hardware with proprietary bridging extensions
- Radio output power: Max: 21dBm (Set to local regulatory requirements to comply with transmit, conducted and EIRP power limits)
- Data Rate: 1 to 108 Mbps
- Sensitivity: -73 to –91dBm
- Modulation: 64QAM, 16QAM, QPSK, BPSK
- Point to Multipoint, Point to Point, Repeater (See Ordering Guide)
- AI108-4958-BSU, AI108-4958-ON2 - Order a Sector, Omni, GRID, or Panel AI108-4958-SU and -1: Flat Panel Directional AntennaAI108-4958-0-xxx: 23 dBi integrated or 28 dBi external directional antenna. External antennas may be used with local regulatory app
- Up to 7.5 miles (12 km) with built-in 23 dBi panel antennasUp to 30 miles (48.27 km) with max radio output power and optional external 34.5 dBi antennas
- Up to 30 miles (48.27 km) - N-type version (AI108-4958-ON-xxx) with max radio output power and optional external 34.5 dBi antennas
- _
- _
- Ordering Information
- WirelessGRID Worldwide Frequency Channel Plan
- Appendix A – Bench Test Procedure
- _
- Step 1. Setup a wired Ethernet network between test stations
- Step 2. Setup wired Ethernet network connections to bridges
- Step 3. Setup bridge software configuration for bridge
- Step 4. Test network connectivity across a WirelessGRID link
- Step 4a. Check throughput of WirelessGRID link (optional)
- Step 5. Running the real-time Signal Strength Monitor
- Step 6. Field deployment of WirelessGRID bridges
- Appendix B. Multi-point Bridge Configuration Log
- Appendix C: Weatherproofing RF Cable Connections
- How to Get Help
Airaya – Fast and affordable outdoor wireless bridges
System Requirements
Before installing the WirelessGRID bridge, be sure you have the following
items on-hand:
An AC power outlet (100 to 240 V, 50 to 60 Hz) to supply power to
the indoor injector units on both sides of the wireless link
An outdoor unit mast with a 1 to 6 inch (25.4 to 152.4 mm)
diameter
An available RJ-45 (UTP) port on a 10/100 Mbps Ethernet switch or
router
Web browser for software configuration
The WirelessGRID bridge has been designed to withstand normal handling
procedures, but reasonable precautions should be taken during
installation, particularly with regard to static discharge.
• Make sure that you are adequately grounded by touching the bare
metal surface on the back of a computer or networking device
before installing the indoor and outdoor units.
• Avoid moving around the work area in order to eliminate static
charge buildup.
• If possible, do not work on a carpeted area.
- 13 -