TROUBLESHOOTING
Trouble
Probable Cause
Remedy
Digital display not
illuminated.
• No Power.
• Power button has not
been depressed.
• Check 120 volt power source.
• Press power button once to
turn on.
Fan not operating
(digital display is
illuminated).
Room 3% or more below
SET humidity level.
Bottles are empty.
• Raise SET humidity level if
desired.
• Increase fan speed.
• Fill humidifier with water.
Fan running
continuously.
• SET humidity level is
65%.
• ROOM humidity level
has not reached 1% or
more above SET
humidity level.
A SET humidity percentage of
65% operates fan continuously.
Adjust SET level between 25%
- 60%.
• Continue to run until desired
humidity level is achieved. This
may take up to 48 hours initially.
Poor evaporation of
water.
CHECK FILTER (CF)
message flashing.
• Mineral buildup on filter
(wick).
• Change to new wick
NOTE: Local water varies from
area to area and under certain
conditions minerals will build up
more rapidly in the wick.
• Unplug unit for 1-2 minutes to
reset CF function
Neither bottle
emptying.
Unit is not level
Bottle valve stem is not
positioned correctly
• Dirty wicks.
Ensure unit is placed on level
area
• Check orientation of bottles.
Reposition so that bottle
valve stem is depressed by
post in bottom of cabinet.
• Change to fresh wicks
Left bottle not
emptying.
• Right bottle contains
water.
•The humidifier is designed so
that right bottle empties first.
• Ensure unit is level
Water leaking from
unit
Bottle caps not properly
tightened or situated
Check that valve stem is secure
and bottle cap is tight and
correctly aligned in base.
Control panel does
not respond to input.
Display shows CL
• Control lock feature has
been turned on to
prevent changes in
settings.
• Press Humidity and Speed
buttons at same time for 5
seconds to deactivate feature.
Display flashes “20” Room Humidity is
lower than 20%.
• Will read actual humidity when
level comes up to 25%.
Display flashes ”—“ • Unit initiating.
• Room humidity is over
90%.
• Room humidity will display after
initiation is complete.
• Will remain until humidity drops
below 90%.