SPECIFICATIONS
Important Warnings - Die Grinders
1. Only use mounted grinding stones or mounted carbide burrs that meet ANSI standards, ISO standards or both.
2. Never adjust the die grinder, adjust the collets or change the mounted stones or mounted burrs unless the air supply and air hose is
disconnected from the die grinder.
3. Only personnel trained in the correct methods to adjust collets and change mounted stones and mounted burrs should conduct these
operations.
4. Always ensure that you are aware of the direction of the sparks being created by the grinding operation and ensure that the sparks are
not directed toward the operator or other persons in the area.
5.
6. Only use mounted stones or carbide burrs that have the correct spindle diameter that matches the original collet size provided by the die
grinder manufacturer.
7. Particular care must be taken not to use metric size mounted stones and mounted burrs with die grinders that have imperial size collets,
or use imperial mounted stones and mounted burrs with die grinders that have metric collets.
Model No.
Free
Speed
(RPM)
Motor
(HP)
Collet
Size
(in)
Gears Exhaust
Weight
(lbs.)
Length
(in)
Air Cons.
(CFM)
Rec. Hose
Size
(in.)
Air Inlet
(in.)
6201 22,000 1/2 1/4 Direct Drive Rear 1.1 8.5 6 3/8 1/4 NPT
Tools of this class operate on a wide range of air pressure. It is recommended that air pressure of these tools measures 90 PSI at the tool while running free. Higher
pressure and unclean air will shorten the tool’s life because of faster wear and may create a hazardous condition and void the warranty. Water in the air line will
cause damage to the tool. Drain the air tank daily. Clean the air inlet lter screen on at least a weekly schedule. The recommended hookup procedure can be viewed
in the illustration below. The air inlet, used for connecting air supply, has standard 1/4” NPT American Thread. Line pressure should be increased to compensate for
unusually long air hoses (over 25 feet). Minimum hose diameter should be 3/8” I.D. and ttings should have the same inside dimensions.
Air Supply