Owner`s manual

IBIS Mk II Installation Instruction
6/8/2010 Page 1 of 9
Installation Instructions - Ibis Rooftop Reverse Cycle Air conditioner
1. Consider Installation position
Before you begin, mark out the position of the unit considering the following important requirements for positioning unit on rooftop.
The air conditioner should be situated as centrally as possible on the van, to give even air distribution within the air-conditioned space.
Avoid an installation position where a bulkhead, cupboard or return could interfere with the discharge air flow from the inside plenum.
The outside unit needs to conform to the figure below
It is important that the unit is never more than 5° from the horizontal and the rear of the unit should never be higher than the front.
If your installation is likely to exceed these limits contact Aircommand for specialist advice
NOTE POSITION OF TWIN
CONDENSER EXHAUSTS
HOT AIR IS EJECTED FROM THESE EXHAUSTS
CONSIDER HATCH POSITIONS AT THE REAR
OF THE UNIT
REAR OF
UNIT
MINIMUM 200MM CLEARANCE
FROM REAR GRILLE TO ANY
VERTICAL FACE
MINIMUM 100MM CLEARANCE
TO ANY 45 DEGREE FACE
MINIMUM 25MM CLEARANCE
FROM SIDE GRILL TO ANY
OBSTRUCTION
THE OUTLINE SHOWS THE MINIMUM CLEARANCE
REQUIRED AROUND THE IBIS ROOF UNIT
DISTANCES SHOWN ARE CALCULATED FROM A
14” SQUARE HOLE (356X356MM)
CALL AIRCOMMAND FOR ADVICE IF YOUR INSTALLATION
DIFFERS SIGNIFICANTLY
DIRECTION OF
TRAVEL
14 inch
square
hole
IMPORTANT NOTE:
FRONT OF UNIT MUST FACE DIRECTION OF TRAVEL
FAILURE TO FOLLOW THIS INSTRUCTION WILL RESULT IN
DAMAGE TO CONDENDER FANS
DIRECTION OF
TRAVEL
FRONT OF
UNIT
REAR OF UNIT