Section 7 (Continued) Wiring Harness
23
Connecting the AirDog® Relay Control to the ECM
7-2. Disconnect the OE fuel pump lead from the ECM pump lead. The Original Equipment
fuel pump lead extends about 5 inches from the pump. The Deutsch, two pin connector
is at the end of this lead. Look for it below and to the rear of the filter canister.
7-3. Carefully route and connect the AirDog® relay lead, the Grey Deutsch two pin connector
on the AirDog® wiring harness, to the ECM pump lead.
Connecting the Power Supply Leads to the Alternator or Battery
Note: Connecting the power supply leads to the alternator instead of the battery will create a
corrosion resistant connection.
7-4A. Route the Red and Black power supply leads to the alternator. Connect the Black (-) lead
to the alternator Chassis Ground connection. Connect the Red (+) lead to the alternator
Hot Lead going to the battery.
Figure 53
Black (-)
Red (+)
Replace the Protective Cover
Figure 55
Figure 56
Figure 54