Sky Parlor READ AND SAVE ALL INSTRUCTIONS INSTRUCTION MANUAL WARRANTY CERTIFICATE
This product is protected by United States Federal and/or State Law, including Patent, Trademark and/or Copyright laws. Manual design and all elements of manual design are protected by U.S. Federal and/or State Law, including Patent, Trademark and/or Copyright laws. 1151 W.
WARRANTY The Aire warranty is for one (1) year from the date of purchase from an authorized Aire dealer. This warranty is only valid to the original purchaser or user against all defects in material and workmanship (light bulbs excluded) for one (1) full year. Additionally, Aire warrants the motor only for the lifetime of the Aire ceiling fan (excluding wall controls and electrical components), to the original purchaser or user. • The warranty is void with the use of any non-Aire electrical devices; e.g.
SAFETY RULES 1. To reduce the risk of electric shock, ensure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National Electrical Code “ANSI/NFPA 70-1999” and local electrical codes. Electrical installation should be performed by a qualified licensed electrician. 3. The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 lbs.
PACKAGE CONTENTS Unpack your fan and check the contents. You should have the following items: 13. 12V MN21/A23 battery 14. Balancing kit 1. Fan blades (5) 2. Blade holders (5 ) 3. Hanger bracket 4. Canopy 5. Canopy cover 6. Downrod assembly 7. Coupling cover 8. Fan motor/housing assembly 9. Mounting plate 10. 20 Watt LED light kit 11. Glass Shade 12. Remote control with holder and 2 mounting screws 3 A. Mounting hardware: #10 x 1.5" Wood screws (2 PCs.) #8 x 3/4" Machine screws (2 PCs.
INSTALLING THE FAN Tools Required: Phillips screw driver; slotted screw driver; step-ladder; wire cutters; electrical tape. MOUNTING OPTIONS If there isn't an existing mounting box, then read the following instructions. Disconnect the power by removing fuses or turning off circuit breakers. Secure the outlet box directly to the building structure. Use appropriate fasteners and building materials. The outlet box and its support must be able to fully support the moving weight of the fan (at least 50 lbs.).
HANGING THE FAN WARNING: All of the parts, hardware and components such as the hanger bracket and hanger ball have been provided for your safety and the proper installation of your new ceiling fan. The use of other parts, hardware or components not supplied by Aire with the fan will void the Aire Warranty. REMEMBER to turn off the power. Follow the steps below to hang your fan properly: Step 1. Secure the Hanger Bracket to the ceiling outlet box using the screws provided with your outlet box in conjunction.
ELECTRICAL CONNECTIONS WARNING: To avoid possible electrical shock be sure electricity is turned off at the main fuse or breaker box before wiring. NOTE: The Aire Control® System for this DC motor fans is equipped with a learning frequency function which has 32 code combinations to prevent potential interference from other remote units. The frequency on your Receiver and Transmitter units have been preset at the factory. (Fig.
FINISHING THE INSTALLATION Step 1. Remove 1 of the 2 screws from the bottom of the hanger bracket and loosen the other one half a turn from the screw head. Step 2. Slide the canopy up towards the hanger bracket and place the key hole on the canopy over the screw on the hanger bracket, turn canopy until it locks in place at the narrow section of the key holes. (Fig. 13) Step 3. Align the circular hole on canopy with the remaining hole on the hanger bracket, secure by tightening the two set screws.
ATTACHING THE FAN BLADES Step 1. Attach the fan blades to the blade holders using the screws and fiber washers provided, tighten screws and fiber washers securely. Repeat process with other blades. (Fig. 14) Step 2. Align motor holes to blade holders and secure with screws and lock washers provided, tighten screws securely. Repeat process with other blades. (Fig. 15) SCREWS AND FIBER WASHERS MOTOR FAN BLADE SCREWS BLADE HOLDERS FIG. 14 BLADE HOLDER ASSEMBLY FIG.
INSTALLING THE LED LIGHT KIT NOTE: Before starting installation, make sure power is turned off at the circuit breaker. CAUTION: The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is required, the product should be returned to an authorized service facility for examination or repair. Step 1. Remove 1 of the 3 screws from the mounting plate and keep it for future use. Loosen the other 2 screws. (Do not remove) Step 2.
INSTALLING THE GLASS SHADE Raise glass shade up against mounting plate and secure it to the fan by turning the glass shade clockwise until snug. DO NOT OVERTIGHTEN. (Fig. 18) GLASS SHADE FIG.
OPERATING THE REMOTE CONTROL Remote Control only: Install an A23 12 volt battery (included). To prevent damage to transmitter remove the battery if not used for long periods of time. IMPORTANT: THIS REMOTE CONTROL & DC FAN MOTOR ARE DESIGNED TO PERFORM A ONE TIME SELF CALIBRATION TEST. THIS TEST WILL BEGIN ONCE A NEW CODE HAS BEEN SET, AND WILL LAST APPROXIMATELY SIX MINUTES. Your DC brushless motor is equipped with a self learning frequency function remote control.
Speed settings for warm or cold weather depend on factors such as room size, ceiling height and number of fans. The reverse switch is located on the top of the motor housing. Slide the switch to the left for warm weather operation. Slide the switch to the right for cool weather operation. NOTE: wait for fan to stop before changing the setting of the slide switch. Warm Weather (forward) A DOWNWARD airflow creates a cooling effect as shown in Figure 20.
CARE OF YOUR FAN Here are some suggestions to help maintain your fan. 1. Because of the fan's natural movement some connections may become loose. Check the support connections, brackets and blade attachments twice a year. Make sure they are secure. (It is not necessary to remove fan from the ceiling). 2. Clean your fan periodically to help maintain its new appearance over the year. CAUTION: many common household cleaning products contain chemicals that could damage the finish of your fan.
TROUBLESHOOTING SYMPTOM SOLUTION Fan will not start Check to make sure the wall switch is turned on. Check circuit fuses or breakers. Caution! Make sure the power is turned off before performing the following steps. Remove canopy and check wire connections. Check wall control transmitter connections (if applicable). Note: Fan must be installed at a maximum distance of 40 feet from the transmitting unit for proper signal transmission between the transmitting unit and the fan's receiving unit.
SPECIFICATIONS Fan Size Speed 56" Volts Amps Watts RPM CFM N.W. G.W. C.F. 2.09' Low 120 0.07 3.70 51 2452 7.8 9.03 High 120 0.62 46.16 141 6414 kgs kgs These are typical readings. Your actual fan may vary. They do not include amps and wattage used by the light(s).