LN OS FIREMAN Portable Air-conditioner APACE Use and Care Manual Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before installing and using this appliance. Please keep this Use and Care Manual proper for future reference.
Contents Safety Instructions. Functions and Technical Specification... 4 Features and Identification of eee 4 Operation and Renee nnn) 5 Lae 9 Handling and rss rennin eases sss ens 10) Installation and Adjustment iii 10 Drainage Instruction.. Maintenance and eee me ne enemas 14 End of Season Storage eee eee 15 Troubleshooting. eee eee nes Warranty terms and conditions...
Safety Instructions 1. Electrical Specifications 1.All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding to the following instructions, contact a qualified electrician. 2.The unit must be installed in accordance with national wiring regulations. Check available power supply and resolve any wiring problems before installation and operation of this unit. 3.
3. Cautions: Keep the unit at least 1 meter away from TV or radios to avoid electromagnetic interference. Do not expose the unit under direct sun light to avoid surface color fading. Do not tilt the unit for more than 35 degrees or upside-down while transporting. Place the unit on a flat surface and upright with less than 5 degrees inclination. The unit operates more efficiently in certain room locations (see Installation and Adjustment).
Function and Technical Specification This unit offers cooling, dry, fan and sleep modes, idea for home and office use; This unit is with two fan-speed levels accessible by panel control and remote control. Temperature setting range of this unit is . This unit is designed with various protection functions such as 24-hour programmable timer, auto condenser circle, super intelligent temperature sensor and water-full control and waning etc. Features and Identification of Parts 1.
1. LED Display 2. Operational Buttons 3. Vertical louvers 4. Horizontal louvers 5. Air Outlet Window 8. Front Panel 7. Universal Wheel 8. Back Panel 9. Main Vertical Louver 10. Horizontal louvers connecting rod 11. Vertical louvers connecting rod 12. Handle 13. Protective Grid of exhaust air outlet Operation and Setting This section explains proper mobile air conditioner operation 1. Control Panel 14. Universal plug fixing holes 15.
On/Off button Mode button Up button Timer button G Timer indicator ge Water full indicator 5 Fan mode indicator gy Dehumidify made indicator Fan speed button Down button A v High speed A Low speed indicator indicator se Sleep mode Remote control signal | Cool made indicator J) 3 indicator 2 receiving window Celsius/ Fahrenheit ay LED display window Operation indicator | ¢ temperature indicator 2. Control Panel Operation: This unit is with Cool, Dehumidifying, Fan and Sleep modes operations.
When room temperature is higher than set temperature, the compressor and fan will start to run. When room temperature is lower than set temperature, the compressor will stop working and fan keep running at original speed. The temperature can be set within a range of and fan speed can be adjusted to high or low level. Unit On/Off time can be set. protection available (see Troubleshooting). Water-full waning function. Fan made: Fan runs at set speed, and compressor will not work. Fan speed can be adjusted.
then room temperature will show in LED display window. ® Press “Timer” to check time remained when “Timer” function is on; Press “Timer” twice within 5 seconds to cancel timer. ® Only final time setting is effective if repeated setting. ® The time can be adjusted within a range of 1-24 hours, press A or ¥ buttons, to increase or decrease 1 hour by pressing once. ® Unit will not change working made after timer set. Timer will not stop by other functions.
Be sure to note proper polarity of batteries Notes: ® Use alkaline batteries only. Do not use rechargeable batteries. ® When replace batteries, always replace both batteries with new batteries, do not mix old and new batteries. ® If air conditioner will not be used for an extended period of time, remove the batteries from the remote control.
Handling and Transportation Hold the top of the air outlet in front panel with one hand and the handle at the top of back panel with another hand to move the unit in upright position Notes: ® Do not hold the horizontal louvers by hand. ® Make the unit in the upright position whatever handling or moving it. ® Drain the water in the unit completely to prevent water leakage or wet the floor or carpet before handling or moving the unit.
Slant Panel A ® Take two ends of exhaust hose and adapter assembly. ® Hold the unit by one hand, Camry the exhaust hose assembly with another hand and push it into unit gently, fasteners will lock automatically.
3 Installation of window seal-plate ® Open the window in half, put the seal-plate into window, ® Extend seal plate parts and adjust it to the length of window, fix it with screws then. Remarks: ® Keep two ends of window seal-plate to meet the window edges well, to assure seal effect. ® Tum the screw in good position. 4. Installation of the unit ® Move the unit installed exhaust hose assembly in front of the window and keep the unit at least 50cm away from the walls or other objects.
Remarks: ® Slide the adapter downwards and assure adapter installed in good position. ® Lock the screw tightly to avoid fall off. ® Exhaust hose can't be bent or with flexible higher than 45°, in order to keep good ventilation. Important notes: The exhaust hose is 280mm-1500mm long and which is determined by the specification of the air-conditioner (s). Do not use prolonged the hose or replace it with other different hoses as this may affect the functions of the air-conditioner.
Water Stopper Drain cap “> Drainage Hole ~~ Drain hose Notes: ® Drain hose must be installed before unit starts working. ® Otis suggested to use manual drainage when unit in cooling mode, to ensure enough water to recycle in the unit to cool condenser and enhance cooling performance. ® Put the drain hose in an inaccessible place, not higher than drainage hole and keep drain hose straight without any flexible. ® Keep the drain cover and its stopper properly installed when continuous drainage is adopted.
Notes: Do not squash the mesh. Do not hit the mesh with sharp objects or brush. 2.2 Installation of the filter Aim the end of the filter toward to slot then push it gently into slot in even force. Special note: ® Be sure to install the filters to side panel at first then install the filter into back panel. ® Install the filter with opposite direction of removal. ® Install the filter into place gently to avoid any damage to filter. End of Season Storage 1.
Troubleshooting Please check unit and suggestions below before asking for professional service, but never dismantle or repair the unit by yourself, it may cause harm to you and your property. Ambient temperature too low or too high? Trouble Cause Remedy , Connect the unit to a live socket and turn it Power supply failure on. Water-full and its indicator lighting Drain the water stored in the unit. The unit fails to start up It is recommended to use this unit between 50-95°F .
Appendix For pacific technical parameters of the model, refer to rating label on the product. x Correct Disposal of this product This marking indicates that the product should not be disposed with other household wastes throughout the USA. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources.
Warranty Terms & Conditions FIREMAN Question about your product? We are here to help. Visit us at: www.alremaxusa.com Or call our Customer service hotlink: 1-858 475 9647 Under normal operations, the product will guarantee a 1-year full warranty provided by FIREMAN {effective from the date of purchase). In Order to Make a Warranty Claim During the First 90 Days from the Date of Original Purchase: 1.Properly pack your unit. We recommend using the original carton and packing materials. 2.