LN FIREMAN Portable Air-conditioner APELIKE Use and Care Manual Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before installing and using this appliance. Please keep this Use and Care Manual properly for future reference.
Safety Instructions 1.All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding to the fallowing instructions, please contact a qualified electrician. 2.The unit must be installed in accordance with national wiring regulations. Check available power supply and resolve any wiring problems before installation and aeration of this unit. 3.
instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Cautions % Please make sure that the unit is placed on a flat, dry place. Keep the unit between the walls around has more than tetrameters. Keep the unit at least 1 meter away from TV or radios to avoid electromagnetic interference.
3% 24-hour Timer function, unique on/off reminding music. 3% 3-minute re-start delay protection to compressor and other multiple protection functions. % Unique exhaust hose and fasteners, convenient installation. 2. identification of Parts a3 # 1. Control panel 11. Upper filter assembly 2. Wind Grille 12. Lower filter assembly 3. Display Screen 13. Drain hole and cover 4. Front shell 14. Remote Control 5. Universal wheel 15. Exhaust hose assembly 6. Handle 16. Exhaust hose adapter 7. Universal socket 17.
Operation and Settings 1. Control panel instructions LU T Med =2 L Heat Cool Dehumidify Fan Power Fan BUTTONS A. TIMER BUTTON Program the time from 1 hour to 24 hours for the unit to turn ON or OFF. When a TIME DELAY is programmed, the Timer indicator light will illuminate. While the unit is operating: 1. Press the TIMER button. 2. Press the UP/DOWN arrow buttons to select the number of hours you want the unit to continue to operate before turning off.
The temperature can be set between 62°F and and the air conditioner is in COOL mode. 1. Press the MODE button until the COOL mods is selected. 2. Press the UP ARROW or DOWN ARROW buttons to select the temperature. Note: The temperature cannot be set when the air conditioner is in dither FAN or DRY mode. D. MODE BUTTON Press MODE button to toggle among the operating options. The corresponding indicator will illuminate. COOL Coals the room to the set temperature. DEHUMIDIFY Reduces the humidity in the room.
1. Press and glide the battery cover on the back of the remote control, then you can remove the cover. 2. Insert two new alkaline AAA batteries into the battery compartment. Be sure to note the proper polarity. 3. Reattach the battery cover and make sure the locking tab clicks into place. Be sure to note proper polarity of batteries Notes: ® Use alkaline batteries only. Do not use rechargeable batteries.
Protection functions 1. Water-full protect: Use Water switch to achieve water-full protect, water switch is always off, it will be on when it works. both water-full indicator and “FL” on LED window is flashing. 2. Anti-freeze protection function Compressor, water spraying motor will tum off when compressors are running over 10 minutes and tube temperature (Tp} is continuously =2 for 20 seconds under cooling mode , E4 will show on LED display window.
Installation & Adjustment 1. Installation Warning: Keep this mobile air-conditioner in upright position at least 2 hours before first installation. This air-conditioner may be moved indoors conveniently; keep the unit in upright position while moving it. The air-conditioner shall be placed on flat and hard surface. Do not install or operate this air-conditioner in bathroom or other wet environments. 1.
1.3 Installation of the unit 1. Move the unit together with its exhaust hose assembly in front of the window and keep the unit at least 50cm away from the walls or other objects. 2. Install the rectangle end of exhaust hose adapter into the corresponding rectangle hole in window seal-plate assembly, fix it with screw and close the window. A. Align the 4 locks on window seal-plate with corresponding 4 fasteners on exhaust hose adapter and set them together, then slide adapter downwards. B.
air-conditioner {s). Do not use prolonged the hose or replace it with other different hoses as this may affect the functions of the air-conditioner. The exhaust hose must be smooth or it may lead air-conditioner overheat and rip because exhaust hose is abstracted. Drainage Instruction This portable air conditioner has two drain ports, higher one and lower one and we can use two drainage methods: manual drainage and continuous drainage; 1.
3. Put the drain hose in an inaccessible place, not higher than drainage hole and keep drain hose straight without any flexible. 4. Keep the drain cover and its stopper properly installed when continuous drainage is adopted. Water outlet ’ Drain hose Drain cover 3. Continuous drain in humidification mode: higher drain port Is the best. 1} Screw off the drain cover and unplug the water stopper. 2) Connect drain-hole with ¢13mm PVC drain hose, into depth of mm-10mm.
Maintenance and Service Tum off the unit and pull out the plug before maintenance or send the unit to service center. 1. Surface cleaning Clean the unit surface with wet and soft cloth, but do not use chemical solvents such as alcohol and gasoline to avoid any damage to unit. 2. Filter cleaning Clean the filter every two weeks Note: If filter is blocked by dust or any other things, it would influence the unit performance. 3.
1) Aim at slot and push filters in even force toward into slot gently to avoid any damage. 3. Clean of handle position and remote control storage area. 1) Take out the remote control. Remote control storage area 2) Clean the handle position and remote control storage area with wet and soft cloth. Note: Do not drip water into the unit. End of Season Storage 1. Screw off the drain cover, and then pull out the stopper to drain water completely. Note: The tilt angle of the unit must be =30 2.
Troubleshooting Please check the unit and suggestions below before asking for professional service, but never dismantle or repair the unit by yourself, it may cause harm to you and your property. Trouble Cause Remedy The unit fails to start up Power supply failure Connect the unit to a live socket and tum it on. Water-full and its indicator lighting up Drain the water stored in the unit.
Appendix Schematic diagram of the air conditioner Capillary Condenser L NN Compressor Evaporator For specific technical parameters of the model, refer to rating label on the product. \/fi Correct Disposal of this product L This marking indicates that the product should not be disposed with other household wastes throughout the world. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources.
Warranty Terms & Conditions FIREMAN Question about your product? We are here to help. Visit us at: www.airemaxusa.com Or call our Customer service hot-line: 1855 475 9647 Under normal operations, the product well guarantee a 1-year full warranty provided by FIREMAN (effective from the date of purchase). In Order to Make a Warranty Claim During the First 90 Days from the Date of Original Purchase: 1.Properly pack your unit. We recommend using the original carton and packing materials. 2.