Specifications

A5
1 - Hose (2VP2-1012), quantity as required by applicable unit (1 hose per cartridge).
Figure 7.
7. Remove the old Vibra Pulse
hose. This is done by loosening the hose clamp securing the spring at the
top of the VP hose where the VP hose attaches to the 3/8” hose barb. Slide the spring and hose clamp
down the VP hose and set aside for later use. Next, remove the old VP hose, this is sometimes easiest to
do by cutting the hose at the top, where it fits over the hose barb, to allow free removal. Discard old
hose after removing.
8. Loosely place hose clamp (retained from step above) into the first closed loop of the spring after first
opening clamp to maximum diameter, see Figure 8.