Operating instructions
AFLR48 Ceiling Sweep Fan Installation Instructions
3 of 4
©
Schneider Electric (Australia) Pty Ltd.
All Rights Reserved.
Requires additional components (not supplied with this fan) including:
• Clipsal 30M Switch Mechanism
• Two gang grid plate and cover
8.0 Operating Instructions
• Turntheknobtospeed3(topposition).Thiswillstartthe
blades spinning.
• Oncethebladesarespinningyoucanselectalowerspeed,
if desired.
• Thespeedsettingisalwayslocatedatthetoppositionofthe
knob, as illustrated below.
Fan with Light
7.0 Connecting the Speed Controller
with a Light Switch
6.0 Connecting the Speed Controller
All Airflow Ceiling Sweep Fans come complete with a three speed,
flush fitting, capacitor controller.
This controller fits to standard 84mm fixing centres, the same as a
normal switch or power point.
Although supplied standard in the vertical format, the mechanism
can be rotated 90° to provide a horizontal format.
To ensure that the ‘off’ position of the switch is at the top when
installed, the mechanism must be installed into the gridplate with
screw heads pointing upwards.
Three is the highest speed, one is the lowest.
• Removeswitchsurround.
• Terminatecables,asillustratedinthebelowdiagram.
• ActivetoCommonandSwitchedActivetoterminalone.
• Fixcontrollertowallboxorbracketusingscrewsprovided.
• Screwsmayneedtobeshortenedforsomeapplications.
• Replaceswitchsurround.
Fan Only
Top Position
3
2
OFF
1
ACTIVE
SWITCHED ACTIVE
(TO FAN MOTOR)
COM
2
1
3
Capacitor
RED
ORANGE
PURPLE
Rotary Switch Mechanism
COM
ACTIVE
SWITCHED
ACTIVE (Fan)
2
1
3
Capacitor
COM
L
2
1
SWITCHED
ACTIVE (Light)
Clipsal 30M Switch
Mechanism
Rotary Switch