Product manual
Model #RB3-065/035 13 R20140519
Figure 8
4. While watching the included vacuum gauge installed at the
gripper’s auxiliary port, open the valve connected to the gripper’s grip
port and observe the vacuum generation speed. You should be able to
observe performance very similar to Figure 9.
Figure 9
5. Switch back and forth between opening the grip and release ports
several times to make sure performance similar to Figure 9 is
achieved. Detailed measurements are not necessary. Simply
confirming that the gripper reaches ~25 inHg vacuum in less than 1.5
seconds is sufficient.