Service manual
18
19
V-PACKING REPLACEMENT KIT
SEVERE DUTY- PART NO. 187-040
Contains: Leather & Plastic Packings,
Teon & Viton O-Rings, Balls &
plastic dual sided female adaptor
& Larger Male Glands.
GLAND KIT - PN 187-064
V-PACKING REPLACEMENT
INSTRUCTIONS
1. Remove the uid pump as per the "Fluid Pump
Disconnect" instructions on page 17.
2. Unscrew and remove the inlet valve per
instructions on page 18.
3. Unscrew & remove the packing nut (187-046).
Push the piston rod down through the packings
and out of the pump. Utilizing packing removal
tool (187-249) the complete packing set can be
removed quickly and easily. Another method
is to wrap some masking tape around the
bottom of the piston. Now push the piston back
through the pump and remove through the top.
The packings and glands will be removed with
the piston rod, leaving the uid body (187-313)
empty.
4. Disassemble and clean all parts for reassem-
bly. Discard old packings and lower glands.
Save upper glands (187-026 & 187-025) for
reuse.
5. Remove the outlet seat support, outlet seat,
outlet ball, O-ring and ball cage as previously
described on page 18.
187-026
187-030 187-060
187-025
187-031
187-315
187-029 187-059
187-058
187-037
V-PACKING REPLACEMENT
FIG. 8