Instruction manual

14
15
SERVICING THE FLUID PUMP
REFER TO FIGURE 14
1. Follow the Pressure Relief Procedure on page 8.
2. Flush the material you are spraying out of the
machine.
3. Remove the connecting rod shield.
4. Move the piston rod to its lowest position by
cycling pump slowly.
5. Turn off the motor.
6. Disconnect Sensor by holding it in place with a 7/8”
wrench and unscrewing the swivel with a 11/16”
wrench.
7. Remove the retaining ring from the connecting rod
and slide the sleeve down revealing the connecting
rod pin.
8. Remove the suction tube assembly from the uid
pump by unscrewing the suction nut with the packing
adjustment tool (189-211).
9. Using a 1/2” wrench unscrew the two bolts from
the cover assembly. The uid pump will be hanging
loosely at this point.
10.Remove the connecting rod pin out of the
connecting rod, allowing the removal of the uid
pump from the machine.
REFER TO FIGURES 14
. Loosen the packing nut and ensure that the piston rod
is in its upper position in the uid pump body. Slip the
sleeve & the retaining ring over the piston rod.
2. Push the piston rod up into the connecting rod & align
the holes. Insert the connecting rod pin through the
connecting rod & piston. Slip the sleeve up over the
connecting rod pin and insert the retaining ring into the
groove on the connecting rod.
3. Push the two bolts through the tube spacers & screw
them into the cover assembly. Using a 1/2” wrench,
tighten the two bolts evenly (alternating between them)
until you reach 20 ft-lbs.
4. Reassemble lower suction valve assembly by placing
the suction seat, O-ring, suction ball & suction ball guide
in the suction nut & screw onto uid pump body.
5. Reconnect the sensor to the uid pump body. Hold
sensor with a 7/8” wrench and tighten the swivel with a
11/16” wrench.
6. Start the machine and operate slowly to check the piston
rod for binding. Adjust the two bolts, holding the uid
pump body to the cover assembly, if necessary. This will
eliminate any binding.
7. Tighten packing nut clockwise until resistance is felt
against the Belleville Springs, go 3/4 of a turn more. Put
ve drops of Airlessco Throat Seal Oil in the packing nut.
8. Run the machine at full pressure for several minutes.
Release the pressure by following the Pressure Relief
Procedure & readjust the packing nut per step 7 above.
9. Install the connecting rod shield so that the
small hole is in the upper right hand corner.
FLUID PUMP DISCONNECT
FLUID PUMP REINSTALL
1
2
3
8
9
4,5
7
6
10
11
12
13
PARTS LIST FIGURE 14
Item No. Part No. Description
1 119-028 Connecting Rod Pin
2 331-117 Sleeve
3 331-062 Retaining Ring
4 115-019 Hose Connector
5 100-152 Swivel
6 331-034 Suction Nut
7 100-318 Bolts
8 331-209
331-236
Fluid Pump (Lo-Boy)
Fluid Pump (Hi-Boy)
9 331-093 Piston Rod
10 331-074 Tube Spacers
11 331-111 Connection Rod Shield
12 331-038 Connecting Rod
13 331-234 Cover Assembly
FIG. 14