Specifications
18
19
V-PACKING REPLACEMENT
FIG. 20
V-PACKING REPLACEMENT KIT (187-040)
Refer to Figures 20 & 21
Repack Kit contains all leather & plastic V-packings,
O-Rings, balls, dual side adapter and larger metal
male glands.
See the table on page 20 for a complete list of re-
pack kit components.
GLAND KIT (187-064)
Refer to Figures 20 & 21
Gland Kit contains four metal male glands.
See the table on page 20 for a complete list of gland
kit components.
V-PACKING REPLACEMENT
Refer to Figures 18, 19, 20 & 21
1. Remove the uid pump as per the "Fluid Pump
Disconnect" instructions on page 16.
2. Remove and service the inlet valve as described
in the "Servicing Inlet Valve" instructions on page
17.
3. Using the rod collar tool (189-211) unscrew and
remove the packing nut (187-046). Push the piston
rod down through the packings and out of the
pump. Utilizing packing removal tool (187-249) the
complete packing set can be removed quickly and
easily. Another method is to wrap some masking
tape around the bottom of the piston. Now push
the piston back through the pump and remove
through the top. The packings and glands will be
removed with the piston rod, leaving the uid body
(187-313) empty.
4. Disassemble and discard old packings. Clean all
parts that will be reused for reassembly.
NOTE: Save metal upper glands (187-026 &
187-025) for reuse and reassembly.
5. Remove and service the outlet valve as described
in the "Servicing outlet Valve" instructions on page
17.
1
7
6
10
9
8
11
15
14
13
12
12
13
14
Part No. Table for Figures 18