Operation Manual
35
7.1 FUNCTIONAL DIAGRAM
(two cylinder compressors with electric motor)
1 air filter 8 safety valve
2 motor 9 pressure switch
3 and 5 cylinder 10 pressure gauge
6 after cooler 11 air tank
7 non return valve
7.2 MAINTENANCE TABLE
works daily weekly every every
250 hours 1000 hours
drainin
g
condensation water ▀
check
oil level ▀
clean
air filter ▀
refresh oil
(first
time after 50 hrs)
▀
check
V-belt ▀