Operation Manual
30
Dismount the belt protector (r).
Unscrew the fastening bolts on the motor sledge.
Remove the V-belt.
Place the motor at the right
distance
from the pump. Make sure that the
pulley of the motor runs in the same
line parallel with the flywheel on the
pump (see drawing). Tighten the
fastening bolts and replace the V-
belt. Worn V-belts should be
replaced by new ones with the
same size.
Note: Regular maintenance of your compressor will increase durability and
reliability.
ATTENTION !
Checking the oil level and refreshing the oil does not apply to the oil free
models HLO 200/25, HLO 215/25, HLO 300/50 and HLO 300/100.
MAINTENANCE TABLE
works daily weekly every every
250 hours 1000 hours
drainin
g
condensation water ▀
check
oil level ▀
clean
air filter ▀
refresh oil
(first
time after 50
hours)
▀
check
V-belt ▀