Specifications

PRODUCT SPECIFICATIONS Gas Furnace: G96CTN
440 51 4900 01 3
Specifications subject to change without notice.
PHYSICAL DATA
Heating Capacity and Efficiency
0601714 0801714 0802120 1002122 1202422
Input
High Heat (BTUH) 60,000 80,000 80,000 100,000 120,000
Low Heat (BTUH) 39,000 52,000 52,000 65,000 78,000
Output
High Heat (BTUH) 58,000 78,000 78,000 98,000 117,000
Low Heat (BTUH) 38,000 50,000 51,000 63,000 76,000
Certified Temperature
Rise Range ºF (ºC)
High Heat
35 - 65
(19 - 36)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
45 - 75
(25 - 42)
45 - 75
(25 - 42)
Low Heat
30 - 60
(17 - 33)
30 - 60
(17 - 33)
30 - 60
(17 - 33)
30 - 60
(17 - 33)
30 - 60
(17 - 33)
Airflow Capacity and Blower Data
Rated External Static
Pressure (in. w.c.)
Heating 0.12 0.15 0.15 0.20 0.20
Cooling 0.50 0.50 0.50 0.50 0.50
Airflow Delivery
@ Rated ESP (CFM)
High Heat 1055 1240 1345 1575 1820
Low Heat 755 1008 1095 1385 1555
Cooling 1280 1310 1945 2160 2135
Cooling Capacity (tons)
400 CFM/ton 3 3.50 4.50 5 5.50
350 CFM/ton 3.50 4 5.50 6 6
Direct-Drive Motor Type Electronically Commutated Motor (ECM)
Direct-Drive Motor HP 1/2 1/2 1 1 1
Motor Full Load Amps 8.50 8.50 12.80 12.80 12.80
RPM Range 300 - 1300
Speed Selections Variable (Communicating)
Blower Wheel Dia x Width in. 11 x 8 11 x 8 11x10 11 x 10 11 x 11
Air Filtration System
Factory Supplied External Media Cabinet
Field Supplied Filter
Filter Used for Certified Watt Data* NAHA00*06FB
Electrical Data
Input Voltage
Volts-Hertz-
Phase
115-60-1
Operating Voltage Range Min-Max 104-127
Maximum Input Amps Amps 9.30 9.30 13.60 13.70 13.70
Unit Ampacity Amps 12.60 12.60 17.90 18.00 18.00
Minimum Wire Size AWG 14 14 12 12 12
Maximum Wire Length
@ Minimum Wire Size
Feet 29 29 32 31 31
(M) (9.0) (9.0) (9.8) (9.7) (9.7)
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Amps 15 15 20 20 20
Transformer Capacity (24vac output) 40 VA
External Control Power Available
Heating 24.3 VA
Cooling 34.6 VA
Controls
Gas Connection Size 1/2" - NPT
Burners (Monoport) 3 4 4 5 6
Gas Valve (Redundant) Manufacturer White Rogers
Minimum Inlet Gas pressure (in. wc) 4.50
Maximum Inlet Gas pressure (in. wc) 13.60
Manufactured (Mobile) Home Kit not approved for MH use
Ignition Device Silicon Nitride
Heating Blower Control (Heating Off-Delay) Adjustable: 90, 120, 150, 180 seconds
Cooling Blower Control (Time Delay Relay) 90 seconds
Communication System IONt Communicating SYST0101CW
Thermostat Connections R, W/W1, W2 Y/Y2, Y1, G, Com 24V, DHUM
Accessory Connections EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
* See Accessory List for part numbers available.