Specifications

PRODUCT SPECIFICATIONS Split System Heat Pump: HVH8
20 428 51 5900 03
Specifications subject to change without notice.
HVH825
HEAT PUMP HEATING PERFORMANCE EFFICIENCY MODE
INDOOR AIR
HVH825 / FCM4X48***L Heating Efficiency Mode
Outdoor Coil Entering Air Temperature °F (°C)
7 (-13.9) 17 (-8.3) 27 (-2.8)
EDB
°F (°C)
ID SCFM
Capacity MBtuh
Total Sys. KW† ID SCFM
Capacity MBtuh
Total Sys. KW† ID SCFM
Capacity MBtuh
Total Sys. KW†
Total Integ‡ Total Integ‡ Total Integ‡
STAGE 5
65 (18.3)
450
13.73 12.61 1.94
825
20.11 18.34 2.16
825
22.21 19.73 2.08
70 (21.1) 13.57 12.47 2.01 19.90 18.14 2.26 21.97 19.52 2.17
75 (23.3) 13.48 12.39 2.08 19.71 17.97 2.36 21.73 19.30 2.27
STAGE 3
65 (18.3)
340
9.32 8.57 1.42
500
11.26 10.27 1.36
650
13.17 11.70 1.22
70 (21.1) 9.21 8.46 1.48 11.11 10.13 1.42 12.99 11.54 1.29
75 (23.3) 9.10 8.36 1.54 10.96 10.00 1.48 12.82 11.39 1.35
STAGE 1
65 (18.3)
340
9.32 8.56 1.42
500
11.23 10.24 1.35
650
8.59 7.63 0.80
70 (21.1) 9.19 8.45 1.48 11.07 10.10 1.41 8.45 7.50 0.83
75 (23.3) 9.07 8.34 1.53 10.87 9.91 1.47 8.30 7.37 0.88
INDOOR AIR
HVH825 / FCM4X48***L Heating Efficiency Mode
Outdoor Coil Entering Air Temperature °F (°C)
37 (2.8) 47 (8.3) 57 (13.9)
EDB
°F (°C)
ID SCFM
Capacity MBtuh
Total Sys. KW† ID SCFM
Capacity MBtuh
Total Sys. KW† ID SCFM
Capacity MBtuh
Total Sys. KW†
Total Integ‡ Total Integ‡ Total Integ‡
STAGE 5
65 (18.3)
825
25.00 22.75 2.11
825
27.16 27.16 2.11
650
19.19 19.19 1.28
70 (21.1) 24.69 22.46 2.21 26.80 26.80 2.21 19.22 19.22 1.36
75 (23.3) 24.36 22.17 2.31 26.41 26.41 2.31 18.44 18.44 1.42
STAGE 3
65 (18.3)
650
15.11 13.75 1.25
650
17.04 17.04 1.25
650
19.10 19.10 1.27
70 (21.1) 14.89 13.55 1.32 16.77 16.77 1.32 18.78 18.78 1.35
75 (23.3) 14.67 13.35 1.39 16.51 16.51 1.40 18.44 18.44 1.42
STAGE 1
65 (18.3)
650
10.20 9.28 0.80
585
7.58 7.58 0.44
585
9.05 9.05 0.42
70 (21.1) 9.99 9.09 0.85 7.40 7.40 0.48 8.83 8.83 0.47
75 (23.3) 9.81 8.93 0.90 7.22 7.22 0.52 8.62 8.62 0.52
Operation in this area is restricted to maintain reliable system operation and customer comfort. The system will default to the next available stage
Stage 5 - Compressor speed limited to stage four at 7 and stage three at 57 outdoor; Stage 1 - Compressor speed limited to stage three at 7 and 17 and to stage two at 27 and 37 outdoor.
See additional notes on page 45