Installation Manual

484 01 3601 02 8/9/17
Specifications subject to change without notice.
INSTALLATION INSTRUCTIONS
Cased N Coil, UpflowDownflow
END4X, ENW4X
NOTE: Read the entire instruction manual before starting the
installation.
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical shock,
or other conditions which may cause death, personal injury or
property damage. Consult a qualified installer, service agency, or
your distributor or branch for information or assistance. The
qualified installer or agency must use factoryauthorized kits or
accessories when modifying this product. Refer to the individual
instructions packaged with the kits or accessories when
installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Use quenching cloth for brazing operations.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warning or cautions included in
literature and attached to the unit. Consult local building codes
and the current editions of the National Electrical Code (NEC)
NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical
Code CSA C22.1.
Recognize safety information. When you see this symbol
on
the unit and in instructions or manuals, be alert to the potential
for personal injury. Understand the signal words DANGER,
WARNING, CAUTION, and NOTE. These words are used with
the safetyalert symbol. DANGER identifies the most serious
hazards which will result in severe personal injury or death.
WARNING signifies hazards which could result in personal
injury or death. CAUTION is used to identify unsafe practices
which may result in minor personal injury or product and
property damage. NOTE is used to highlight suggestions which
will result in enhanced installation, reliability, or operation.
IMPORTANT: Nitrogen can leak out through the hole that the
needle pierced in the plugs. This does not indicate a leaking coil
nor warrant return of the coil.
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death.
Before installing, modifying or servicing system, always
turn off main power to system. There may be more than
one disconnect switch. Lock out and tag switch with a
suitable warning label.
!
WARNING
PERSONAL INJURY HAZARD
Failure to follow this caution may result in personal
injury.
This coil contains Nitrogen precharge of 15 PSIG.
Release of this pressure through the center of the
rubber plugs is required before removing the plugs.
CAUTION
!
ENVIRONMENTAL HAZARD
Failure to follow this caution may result in environmental
pollution.
Remove and recycle all components or materials (i.e.
oil, refrigerant, etc.) before unit final disposal.
CAUTION
!
CUT HAZARD
Failure to follow this caution may result in personal
injury.
Sheet metal parts may have sharp edges or burrs. Use
care and wear appropriate protective clothing and
gloves when handling parts.
CAUTION
!
UNIT OR PROPERTY DAMAGE HAZARD
Failure to follow this caution may result in property
damage.
Take precautions to ensure Aluminum tubes do not
come in direct contact or allow for condensate run
off with a dissimilar metal. Dissimilar metals can
cause galvanic corrosion and possible premature
failure.
CAUTION
!
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS 1............................
INTRODUCTION 2.......................................
INSTALLATION 2........................................
Airflow 2...............................................
TXV 2.................................................
Inspect Equipment 2....................................
Select Installation Procedure 2...........................
Installation of Furnace Coils 3............................
Connect Refrigerant Piping 5.............................
Connect Refrigerant Liquid and Suction Lines 5.............
Refrigerant Metering Device 5............................
Condensate Drain Line Connection 5......................
Waste Line Connection 6................................
Humidifier Application 6..................................
INTRODUCTION
Use this instruction manual to install indoor coils on upflow or
downflow furnaces. Do not install coil in horizontal position. Coils
are enclosed in a painted casing have factoryinstalled TXV’s.
These coils are used with R410A refrigerant systems.

Summary of content (6 pages)