Installation Manual

484 01 3701 05 3
Specifications subject to change without notice.
A09084
Fig. 3 HorizontalRight Installation of Pan Extension (43, 60, & 61 sizes only)
HORIZONTAL RIGHT INSTALLATIONS
Acceptable for Air Conditioner and
Heat Pump Applications
HORIZONTAL LEFT INSTALLATIONS
Acceptable for Air Conditioner
Only Applications
Application A
Application F
Application B
Application G
Application C
Application H
Application D
Application I
Application E
Application J
Coil
Ductwork
Airflow
Furnace
Coil
Furnace
Ductwork
Airflow
A13416
Fig. 4 Horizontal Installation Applications
Table 1 – Heat Pump Right Hand Applications
Furnace Width In. (mm)
Coil Width In. (mm)
17.5 (445) 21 (533) 24.5 (622)
14 (356) B, C, D, E D, E
17.5 (445) A B, C, D, E D, E
21 (533) A B, C, D, E
24.5 (622) A
- Not permitted.
Table 2 – Air Conditioner Applications
Furnace Width In. (mm)
Coil Width In. (mm)
17.5 (445) 21 (533) 24.5 (622)
14 (356) B, C, D, E, G, H, I, J D, E, I, J
17.5 (445) A, F B, C, D, E, G, H, I, J D, E, I, J
21 (533) A, F B, C, D, E, G, H, I, J
24.5 (622) A, F
- Not permitted.