Owners Manual

Specifications subject to change without notice.
EFFICIENT UP TO 17 SEER/11.7-13.0 EER AIR CONDITIONER
ENVIRONMENTALLY BALANCED R-410A REFRIGERANT
THRU 5 TONS SPLIT SYSTEM
208 / 230 Volt, 1-phase, 60 Hz
REFRIGERATION CIRCUIT
Scroll compressors on all models
Filter-Drier supplied with every unit for field installation
Copper tube/aluminum fin coil
EASY TO INSTALL AND SERVICE
Easy access service valves on all models
External high and low refrigerant service ports
Only two screws to access control panel
Factory charged with R-410A refrigerant
BUILT TO LAST
Baked-on powder coat finish over galvanized steel
Post-painted (black) coil fins
Coated, weather-resistant cabinet screws
Coated inlet grille with 3/8" (10mm) spacing for extra protection (hail guard)
LIMITED WARRANTY*
5 year parts limited warranty (including compressor and coil)
- With timely registration, an additional 5 year parts limited warranty (including compressor and coil)
* For residential applications only. See warranty certificate for complete details and restrictions,
including warranty coverage for other applications.
Model
Number
Size
(tons)
Nominal
Btu/hr
Min.
Circuit
Ampacity
Max. Fuse
or Breaker
Operating Dimensions
depth x width x hei ght in.
(mm)
Ship / Operate
Weight lbs. (kg)
Notes
N4A618GKB 18,000 11.7 20
25-3/4 x 25-3/4 x 35-1/2
(654 x 654 x 901)
154/130 (70/59)
N4A624GKB 2 24,000 14.1 25
31-3/16 x 31-3/16 x 35-1/2
(793 x 793 x 901)
175/144 (79/65)
N4A630GKB 30,000 14.1 25
35 x 35 x 28-11/16
(889 x 889 x 729)
208/178 (94/81)
N4A636GKB 3 36,000 17.9 30
35 x 35 x 28-11/16
(889 x 889 x 729)
213/180 (97/82)
N4A642GKB 42,000 21.4 35
35 x 35 x 38-7/8
(889 x 889 x 988)
261/224 (118/102)
N4A648GKB 4 48,000 25.9 40
35 x 35 x 45-11/16
(889 x 889 x 1161)
284/247 (129/112)
N4A660GKB 5 60,000 32.4 40
35 x 35 x 45-11/16
(889 x 889 x 1161)
289/252 (131/114)
Use of the AHRI Certified TM Mark
indicates a manufacturer's participation in
the program. For verification of certification
for individual products, go to
www.ahridirectory.org .
This product has been designed and manufactured to
meet ENERGY STAR criteria for energy efficiency when
matched with appropriate coil components. However, proper
refrigerant charge and proper air flow are critical to achieve
rated capacity and efficiency. Installation of this product should
follow the manufacturer's refrigerant charging and air flow
instructions. Failure to confirm proper charge and airflow may
reduce energy efficiency and shorten equipment life.

Summary of content (1 pages)