Natural Gas to Propane Conversion Instructions

6 AG- KN018SNP- 01
Specifications subject to change without notice.
Figure 8 Mixer Screw Location
A06432
REINSTALL BURNER ASSEMBLY
To reinstall burner assembly:
1. Attach flame sensor to burner assembly.
2. Install HSI and bracket to burner assembly.
3. Insert one-piece burner in slot on sides of burner box and
slide burner back in place.
4. Reattach HSI wires to HSI.
5. Verify igniter to burner alignment.
6. For Silicon Nitride igniters, see Figure 9.
7. Re-attach Flame sensor wire to Flame Sensor.
Figure 9
Igniter Position - Side View
9/32”
7.1mm
5/16”
7.9mm
A05025
CONVERT GAS VALVE
! CAUTION
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit damage
The gas valve must be converted and pre- adjusted before
operating on propane gas. If not converted and pre- adjusted,
sooting and corrosion will occur leading to early heat
exchanger failure.
! WARNING
FIRE, EXPLOSION, ELECTRICAL SHOCK
HAZARD
Failure to follow this warning could result in personal injury,
death or property damage.
Gas supply MUST be shut off before disconnecting electrical
power and proceeding with conversion.
! WARNING
ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury,
death or property damage.
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF position and
install a lockout tag. There may be more than one disconnect
switch. Lock out and tag switch with a suitable warning label.
Verify proper operation after servicing.
Single Stage Gas Valve
1. Refer to Figure 10.
2. Be sure gas and electrical supplies to furnace are off.
3. Remove caps that conceal adjustment screws for the gas
valve regulators. (See Figure 10)
4. Remove the regulator adjustment screw.
5. Remove the regulator springs (silver).
6. Install the propane gas regulator springs (white).
7. Install the regulator adjustment screws.
8. Turn the adjusting screw clockwise (in) 8.5 full turns. This
will increase the manifold pressure closer to the propane
set point. (See Figure 10)
9. Do not install regulator seal caps at this time.
Figure 10 Gas Valve (Single Stage)
A190068
Remove the natural gas regulator spring (silver)
Install the propane regulator spring (white)
Redundant Auto Gas Valve
A05071