C AIRREX DEHUMIDIFIER USER'S MANUAL MODEL : ADH-100 ▶ It is essential that you read ‘SAFETY INSTRUCTIONS’ carefully ▶ Thank you for purchasing the unit. before use and follow them at all times. Before operation please read this user’s manual carefully. ▶ Keep this manual on hand for reference. ▶ The warranty form is on the last page. Please complete it now and keep it in a safe place. ▶ This unit is specified for use on the rated ▶ We have a policy of continual improving on our products.
TABLE OF CONTENTS ■ SAFETY INSTRUCTIONS 3~4 ■ GENERAL ADVICE BEFORE USE 4 ■ EXTERIOR DESCRIPTION 5 ■ SPECIFICATIONS 6 ■ CONTROL PANEL FUNCTIONS 7 ■ HOW TO SET THE 'OFF' TIMER 8 ■ HUMIDITY CONTROL OPERATION 9 ■ 'ERROR' and WARNING INDICATORS 10 ■ TROUBLE SHOOTING 11 ■ CLEANING AND MAINTENANCE 12 ■ WARRANTY 16 The following instructions are to ensure user’s safety and to prevent any physical injury or material damage. Please read carefully and follow all instructions.
SAFETY INSTRUCTIONS WARNING Use a circuit breaker for the capacity. (It may cause fire and electric shock) The following symbols are for your guidance: Before cleaning, disconnect the unit. (Otherwise risk of electric shock) = You must NOT. = You MUST. Do not use a damaged power cable. (Short, fire or shock hazard) Do not use an extension lead unless of the approved type. (Risk of fire and / or electric shock) Do not place anything on top of the machine.
SAFETY INSTRUCTIONS CAUTION Do not place this unit on uneven, unstable or inclined surface. (This could cause malfunction) When storing this unit, keep it in a dry, cool place. (To prevent corrosion and malfunction) If not being used for some time or if lightening is present, always disconnect from power. (To prevent risk of electric shock, short circuit or fire) Do not spray water onto this unit nor use solvents such as benzene, thinner or alcohol for cleaning.
EXTERIOR DESCRIPTION FRONT VIEW DIGITAL CONTROLLER AIR INLET EVAPORATOR FILTER CONDENSED WATER OUTLET CASTER (REAR 10'') CASTER (FRONT LOCKABLE) BACK & SIDE VIEW BACK HANDLE AIR OUTLET PUMP BUTTON POWER CORD 5
SPECIFICATIONS MODEL ADH-100 Maximum 32 (86℉ 80%) Capacity gal/day Nominal 22 (80℉ 60%) Power supply 115Vac 60Hz 1Ph Air Flow ft³/min 400 Power Consumption kW 1.2 Current Consumption A 10 Refrigerant lb R-410A / 2.2 Dimensions (WxDxH) inch 19.9 x 21.8 x 39.2 Weight lb 132 Air Filter Vinyl Chloride Mesh Catridge Safety Device ▶ High pressure switch ▶ Low pressure switch ▶ 3 min.
CONTROL PANEL FUNCTIONS ⑧ ⑥ ⑦ ⑨ ④ ⑩ ⑤ ③ ① ② ① Power : Use to power on / off. ② Button : Raises or lowers the setting temperature or sleep (off) time. ③ Fan : Controls fan speed. High / Medium / Low ④ Quiet Operation : Set fan speed slower than 'Low', the LED is on. ⑤ Off Timer : To set the length of time, once turned on, that you wish the dehumidifier to run for. You can set 0~24 hours. Time intervals are 0mins. up to 10 hours and then 1 hour between 10 and 24 hours.
HOW TO SET THE ‘OFF’ TIMER This function enables you to set the length of time you want the unit to operate. You can set the time period from 30min. to 24 hours in 30min. and 1 hour increments. Humidity. % 1. When unit is operating, press the 'Off Timer' button and set the length of time you want by pressing ▲ or ▼. Each time you press the button you will increase the 'time to off' period by 30mins. up to 10 hours, and 1 hour up to 24 hours. The display will show 5 for 30min and 1 for an hour.
HUMIDITY CONTROL OPERATION •When you turn ON, the setting humidity is displayed. Current Humidity •You can change setting humidity. % •The display showing the set humidity will blink 3 times. Setting Humidity % •When you push either ▼ or ▲ button, the setting humidity is changed. Setting Humidity % •The display showing the setting humidity will blink 3 times. Setting Humidity % •Limits of Setting humidity.
‘ERROR’ and WARNING INDICATORS Error Code Problem Cause Corrective Action High pressure Blocked air filter Blocked / kinked exhaust duct Ambient temperature is too high Ensure exhaust duct is not blocked / kinked Do not use the air conditioner if ambient temperature is higher than 113℉ Low pressure Verify Electrical Clean Filters and Coils Verify Power (Voltage/Amps) Check Filters Evaporator/Condenser Check Evaporator/Condenser Coils Check refrigerant level and/or refrigerant leak.
TROUBLE SHOOTING TROUBLE NOT WORKING POOR DEHUMIDIFYING CHECK REMEDY Power cable correctly connected Connect cable correctly Power button "OFF" Press POWER button to "ON" Fuse (supply) blown Exchange fuse in board Breaker on switch board tripped Check load capacity and reset Ambient temp. too high Check operating temp. range Filter blocked with dust Clean Filter Dust in heat exchanger Clean heat exchanger Obstacle against inlet side Remove and allow 20"(50cm).
CLEANING AND MAINTENANCE CLEANING THE AIR FILTERS ② ① 1. To remove filters, open the front case ①, and pull towards you. ② 2. Clean the filters with water or compressed air. 3. Clean heat exchanger unit with a vacuum cleaner or compressed air. MAINTENANCE 1. Turn “OFF” at control panel, remove plug from socket. Coil and store cable neatly. 12 2. Keep machine suitably covered to prevent damage by damp, humidity and dust.
MEMO 13
MEMO 14
MEMO 15
WARRANTY (Applicable to first retail purchaser only) AIRREX unit gives the more reliable performance, comfort and durability the more they are used. They are built under a strict quality assurance regime which includes inspection both during and after production and exhaustive reliability testing. In the unlikely event you have any problems, please contact your dealer or distributor.