HOW TO INSTALL & PRECAUTIONS
Selection of the Installation Place
How to Connect Pipes
As the air conditioner should be connected with the tap water tube, its installation near the hydrant is good.
Install it on the even and stable place.
1. Connect the nipple at the water in-taking hole and the water discharge hole of the backside
of the air conditioner. At this time, wind the Teon tape at the thread part and fasten it the main body.
2. Unfasten the nut and ring at the nipple and connect it to the hose, and insert
the hose into the nipple and fasten it by using the nut.
(When connecting the hose, make the cut surface of the hose even.)
3. Connect the water in-taking hole to the tap water tube (or a pressuring pump),
and the water discharge hole to the drain hole.
(Pay attention for not changing the water in-taking hole with the discharging hole.)
4. Connect the discharging hose with the condensed water discharge hole and to the draining hole.
5. Once the pipe connection is nished, open the valve of water supply line so that water is supplied.
At this time, as water is discharged only when the air-conditioner is operated,
check whether water is discharged from the drain hole.
HOSE
HOSE
The Sink
T-type tube
Tap water nozzle
Tap water tube
WATER OUT
WATER IN
DRAIN